Temporal evolution of hemodynamics in murine arteriovenous fistula: A micro-CT based CFD study

In this study, we investigated the hemodynamic characteristics of arteriovenous fistulas (AVFs) in murine models using micro-CT based computational fluid dynamics (CFD). By combining high-resolution micro-CT imaging with ultrasound flow measurements, our methodology offers a cost-effective and efficient alternative to traditional MRI-based approaches. CFD simulations performed at 7 and 21 days post-surgery revealed substantial temporal changes in both geometry and hemodynamics. Geometric analysis showed that the proximal artery diameter increased from 0.29 mm to 0.38 mm, whereas the initial 2 mm fistula segment showed a 21.6% decrease (0.74 mm to 0.58 mm). Blood flow through the AVF nearly doubled from 1.33 mL/min to 2.57 mL/min. Time-averaged wall shear stress (TAWSS) peak values and locations changed from 142 Pa (day 7) within the proximal artery to 200 Pa (day 21) in the stenotic region. The oscillatory shear index (OSI) showed marked elevation at the anastomosis (increasing from 0.22 to 0.48), indicating disturbed flow development. An inverse relationship between TAWSS and OSI was identified, consistent with previous studies. Our methodology demonstrates the capability to analyze relationships between early hemodynamics and subsequent geometric changes. This approach can enable identification of regions susceptible to stenosis development and monitoring of AVF maturation, which can ultimately lead to quantitative metrics to evaluate surgical outcomes and early therapeutic interventions.

Authors

Institutions

Publication Details

Journal
PLoS Computational Biology
Published
2025-08-18
DOI
https://doi.org/10.1371/journal.pcbi.1012985
Citations
1
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
2.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temporal evolution of hemodynamics in murine arteriovenous fistula: A micro-CT based CFD study

Edward Moreira Bahnson, Christine Wai, Lianxia Li, Hong Yuan et al.
1 citations
PLoS Computational Biology
Central Venous Catheters and Hemodialysis
2.52
article

Temporal evolution of hemodynamics in murine arteriovenous fistula: A micro-CT based CFD study

Edward Moreira Bahnson, Christine Wai, Lianxia Li, Hong Yuan, Boyce E. Griffith, Unimunkh Uriyanghai, Prabir Roy‐Chaudhury, Vinay A. Sudarsanam, Gang Xi, Samuel Haddad, Eric W. Livingston
article en
1 citations

Abstract

In this study, we investigated the hemodynamic characteristics of arteriovenous fistulas (AVFs) in murine models using micro-CT based computational fluid dynamics (CFD). By combining high-resolution micro-CT imaging with ultrasound flow measurements, our methodology offers a cost-effective and efficient alternative to traditional MRI-based approaches. CFD simulations performed at 7 and 21 days post-surgery revealed substantial temporal changes in both geometry and hemodynamics. Geometric analysis showed that the proximal artery diameter increased from 0.29 mm to 0.38 mm, whereas the initial 2 mm fistula segment showed a 21.6% decrease (0.74 mm to 0.58 mm). Blood flow through the AVF nearly doubled from 1.33 mL/min to 2.57 mL/min. Time-averaged wall shear stress (TAWSS) peak values and locations changed from 142 Pa (day 7) within the proximal artery to 200 Pa (day 21) in the stenotic region. The oscillatory shear index (OSI) showed marked elevation at the anastomosis (increasing from 0.22 to 0.48), indicating disturbed flow development. An inverse relationship between TAWSS and OSI was identified, consistent with previous studies. Our methodology demonstrates the capability to analyze relationships between early hemodynamics and subsequent geometric changes. This approach can enable identification of regions susceptible to stenosis development and monitoring of AVF maturation, which can ultimately lead to quantitative metrics to evaluate surgical outcomes and early therapeutic interventions.

PLoS Computational BiologyVol. 21(8)
University of North Carolina at Chapel Hill (US), W. G. (Bill) Hefner VA Medical Center (US), Imaging Center (US)
National Science Foundation, Foundation for the National Institutes of Health
Openalex Percentile: Top 11%
Central Venous Catheters and Hemodialysis
2.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.