Development of a vacuum ultraviolet diagnostic system with millimeter resolution for density fluctuation measurements in tokamaks

In this work, we present the first Lyman-Alpha-Based Beam Emission Spectroscopy (LAB) diagnostic system. This system achieves a significantly enhanced radial spatial resolution of ∼3.3 mm compared to conventional BES. The LAB diagnostic monitors the vacuum ultraviolet Lyman-alpha line (n = 2 → 1 transition, 121.53 nm) and has been implemented on the HL-2A tokamak with twenty spatial channels covering the edge plasma region (ρ = 0.73–1.01) for standard HL-2A discharges. Beyond spatial resolution improvements, the LAB system shows over tenfold signal amplification relative to traditional BES. The entire optical assembly has been securely assembled and underwent rigorous testing within a dedicated vacuum chamber interfaced with HL-2A’s main vacuum system. The monochromator provides linear dispersion of ∼0.09nm/mm and successfully resolves adjacent hydrogen isotope emission lines (HI: 121.567 nm and DI: 121.534 nm) using a 100 μm slit. With a temporal resolution of 1 μs, the LAB diagnostic is a powerful tool for investigating localized, small-scale, high-frequency plasma phenomena in tokamaks.

Authors

Institutions

Publication Details

Journal
AIP Advances
Published
2025-08-01
DOI
https://doi.org/10.1063/5.0281273
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a vacuum ultraviolet diagnostic system with millimeter resolution for density fluctuation measurements in tokamaks

Hao Liu, Rui Ke, Yixuan 艺轩 ZHOU 周, Xu Hao et al.
AIP Advances
Magnetic confinement fusion research
article

Development of a vacuum ultraviolet diagnostic system with millimeter resolution for density fluctuation measurements in tokamaks

Hao Liu, Rui Ke, Yixuan 艺轩 ZHOU 周, Xu Hao, Min Xu, Zihao Yuan, Yi Yu, Guangyi Zhao, L. Nie, Chenyu Xiao
article en

Abstract

In this work, we present the first Lyman-Alpha-Based Beam Emission Spectroscopy (LAB) diagnostic system. This system achieves a significantly enhanced radial spatial resolution of ∼3.3 mm compared to conventional BES. The LAB diagnostic monitors the vacuum ultraviolet Lyman-alpha line (n = 2 → 1 transition, 121.53 nm) and has been implemented on the HL-2A tokamak with twenty spatial channels covering the edge plasma region (ρ = 0.73–1.01) for standard HL-2A discharges. Beyond spatial resolution improvements, the LAB system shows over tenfold signal amplification relative to traditional BES. The entire optical assembly has been securely assembled and underwent rigorous testing within a dedicated vacuum chamber interfaced with HL-2A’s main vacuum system. The monochromator provides linear dispersion of ∼0.09nm/mm and successfully resolves adjacent hydrogen isotope emission lines (HI: 121.567 nm and DI: 121.534 nm) using a 100 μm slit. With a temporal resolution of 1 μs, the LAB diagnostic is a powerful tool for investigating localized, small-scale, high-frequency plasma phenomena in tokamaks.

AIP AdvancesVol. 15(8)
Sun Yat-sen University (CN), Southwestern Institute of Physics (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 91%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of a vacuum ultraviolet diagnostic system with millimeter resolution for density fluctuation measurements in tokamaks — Hao Liu, Rui Ke, et al. · AIP Advances (2025) | TGRS Research Map | TGRS