<b>Background/Objectives:</b> Accurate full-arch impressions are crucial for predictable prosthodontic outcomes. While intraoral scanners (IOSs) are increasingly adopted, evidence comparing their accuracy with conventional analog impressions across full mandibular arches-particularly under both laboratory and clinical conditions using an objective intraoral reference-is limited. Our study aims to evaluate the in vitro and in vivo accuracy of digital impressions compared to conventional methods in full-arch scans using an intraoral reference tool. <b>Methods:</b> In this study, a custom stainless steel transfer aid carrying four 5 mm steel spheres in a trapezoidal configuration, provided with known reference distances, was used. Ten mandibular Frasaco models (in vitro) and ten healthy young adults (18-30 yrs) with intact lower arches (in vivo) received the bonded spheres. Six inter-sphere distances were defined: intermolar (BL-BR), interpremolar (FL-FR), diagonals (BL-FR, FL-BR), and lateral spans (BL-FL, BR-FR). Each arch underwent a digital scan (Medit i700) and a conventional monophase PVS impression, which was poured in Type IV stone and digitized (GOM Scan 1). The inter-sphere linear distances were measured in GOM Inspect, and trueness (deviation from reference) and precision (SD) were calculated. Data normality and homogeneity were verified; parametric <i>t</i>-tests and one-sample tests (α = 0.05) assessed differences between workflows and against reference values. <b>Results:</b> In vitro, analog impressions closely matched reference distances, with only the long-span BL-BR showing minor deviation (0.053 mm, <i>p</i> < 0.001). Digital scans showed significantly greater deviations across all spans (max 0.117 mm), particularly over long distances. In vivo, both workflows demonstrated comparable accuracy: only BL-BR (analog) and BR-FR (digital) differed significantly from the reference, and all AMEs remained within clinical thresholds (≤0.10 mm), except for BL-BR and BL-FL spans. ICC values ranged from moderate to high. Direct paired comparisons revealed statistically equivalent performance across most spans. <b>Conclusions:</b> Analog impressions outperformed digital scans in vitro, particularly across longer spans, confirming their superior dimensional fidelity under controlled conditions. However, in vivo, both workflows delivered statistically comparable and clinically acceptable accuracy. These findings suggest that while analog impressions remain the gold standard for precision-demanding contexts, modern intraoral scanners-when used correctly-can offer reliable full-arch mandibular impressions. The four-sphere reference system proved valuable for objective, anatomy-independent measurement.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-08-19
DOI
https://doi.org/10.3390/diagnostics15162077
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Analog and Digital Full-Arch Mandibular Impressions: In Vitro and In Vivo Evaluation

Diana Cerghizan, Marcel Bojan, Gyula Marada, Alexandra Farcaș et al.
Diagnostics
Dental materials and restorations
article

Accuracy of Analog and Digital Full-Arch Mandibular Impressions: In Vitro and In Vivo Evaluation

Diana Cerghizan, Marcel Bojan, Gyula Marada, Alexandra Farcaș, Izabella Éva Mureșan, Kinga Mária Jánosi, Mircea H. Muntean, Silvia Izabella Pop, Andreea Ana Maria Nechiti
article en

Abstract

<b>Background/Objectives:</b> Accurate full-arch impressions are crucial for predictable prosthodontic outcomes. While intraoral scanners (IOSs) are increasingly adopted, evidence comparing their accuracy with conventional analog impressions across full mandibular arches-particularly under both laboratory and clinical conditions using an objective intraoral reference-is limited. Our study aims to evaluate the in vitro and in vivo accuracy of digital impressions compared to conventional methods in full-arch scans using an intraoral reference tool. <b>Methods:</b> In this study, a custom stainless steel transfer aid carrying four 5 mm steel spheres in a trapezoidal configuration, provided with known reference distances, was used. Ten mandibular Frasaco models (in vitro) and ten healthy young adults (18-30 yrs) with intact lower arches (in vivo) received the bonded spheres. Six inter-sphere distances were defined: intermolar (BL-BR), interpremolar (FL-FR), diagonals (BL-FR, FL-BR), and lateral spans (BL-FL, BR-FR). Each arch underwent a digital scan (Medit i700) and a conventional monophase PVS impression, which was poured in Type IV stone and digitized (GOM Scan 1). The inter-sphere linear distances were measured in GOM Inspect, and trueness (deviation from reference) and precision (SD) were calculated. Data normality and homogeneity were verified; parametric <i>t</i>-tests and one-sample tests (α = 0.05) assessed differences between workflows and against reference values. <b>Results:</b> In vitro, analog impressions closely matched reference distances, with only the long-span BL-BR showing minor deviation (0.053 mm, <i>p</i> < 0.001). Digital scans showed significantly greater deviations across all spans (max 0.117 mm), particularly over long distances. In vivo, both workflows demonstrated comparable accuracy: only BL-BR (analog) and BR-FR (digital) differed significantly from the reference, and all AMEs remained within clinical thresholds (≤0.10 mm), except for BL-BR and BL-FL spans. ICC values ranged from moderate to high. Direct paired comparisons revealed statistically equivalent performance across most spans. <b>Conclusions:</b> Analog impressions outperformed digital scans in vitro, particularly across longer spans, confirming their superior dimensional fidelity under controlled conditions. However, in vivo, both workflows delivered statistically comparable and clinically acceptable accuracy. These findings suggest that while analog impressions remain the gold standard for precision-demanding contexts, modern intraoral scanners-when used correctly-can offer reliable full-arch mandibular impressions. The four-sphere reference system proved valuable for objective, anatomy-independent measurement.

DiagnosticsVol. 15(16)
Technical University of Cluj-Napoca (RO), Universitatea de Medicină, Farmacie, Științe și Tehnologie „George Emil Palade” din Târgu Mureș (RO), National Institute for Research and Development of Isotopic and Molecular Technologies (RO), University of Pecs (HU)
Unitatea Executiva pentru Finantarea Invatamantului Superior, a Cercetarii, Dezvoltarii si Inovarii
Openalex Percentile: Top 78%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.