Temporary Cemented Spacer for Complex Radial Head Fractures: A Case Report

BACKGROUND The management of comminuted and displaced radial head fractures (Mason III), particularly when associated with dislocation (Mason IV) or Essex-Lopresti injury, presents a complex surgical challenge. Treatment options include conservative management, surgical fixation, arthroplasty, or radial head resection; however, no consensus exists regarding the optimal approach for all injury types. Radial head resection is often preferred in complex cases with multiple fragments where reconstruction is unfeasible. While functional and radiological outcomes vary widely, there is a growing trend toward the use of prosthetic implants as the initial treatment to maintain elbow function and stability, with temporary implants employed when definitive ones are unavailable. CASE REPORT We present the case of a 46-year-old patient who underwent radial head resection and received a cemented radial head spacer as temporary management due to the unavailability of a definitive implant. Functional status was monitored over a 21-month period. Our aim was to identify a readily available operating room material capable of effectively neutralizing valgus and axial forces. Since the spacer is intended as a temporary solution, it must be removed or replaced with a definitive implant approximately 4-6 months postoperatively, once stability is reestablished. Beyond this period, bone lysis has been observed. CONCLUSIONS The significance of this case report lies in highlighting alternative options for radial head replacement in complex, irreparable fractures, proposing an easily accessible solution available in any orthopedic operating room. It is further distinguished by its extended follow-up period (21 months) and by providing evidence of the long-term tolerability of cemented spacers - an aspect that has been infrequently reported.

Authors

Institutions

Publication Details

Journal
American Journal of Case Reports
Published
2025-08-19
DOI
https://doi.org/10.12659/ajcr.948197
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temporary Cemented Spacer for Complex Radial Head Fractures: A Case Report

M. A. González León, César Alejandro Jiménez-Aroche, A Saldívar-Moreno, Mariela Hernández-Pavón
American Journal of Case Reports
Bone fractures and treatments
article

Temporary Cemented Spacer for Complex Radial Head Fractures: A Case Report

M. A. González León, César Alejandro Jiménez-Aroche, A Saldívar-Moreno, Mariela Hernández-Pavón
article en

Abstract

BACKGROUND The management of comminuted and displaced radial head fractures (Mason III), particularly when associated with dislocation (Mason IV) or Essex-Lopresti injury, presents a complex surgical challenge. Treatment options include conservative management, surgical fixation, arthroplasty, or radial head resection; however, no consensus exists regarding the optimal approach for all injury types. Radial head resection is often preferred in complex cases with multiple fragments where reconstruction is unfeasible. While functional and radiological outcomes vary widely, there is a growing trend toward the use of prosthetic implants as the initial treatment to maintain elbow function and stability, with temporary implants employed when definitive ones are unavailable. CASE REPORT We present the case of a 46-year-old patient who underwent radial head resection and received a cemented radial head spacer as temporary management due to the unavailability of a definitive implant. Functional status was monitored over a 21-month period. Our aim was to identify a readily available operating room material capable of effectively neutralizing valgus and axial forces. Since the spacer is intended as a temporary solution, it must be removed or replaced with a definitive implant approximately 4-6 months postoperatively, once stability is reestablished. Beyond this period, bone lysis has been observed. CONCLUSIONS The significance of this case report lies in highlighting alternative options for radial head replacement in complex, irreparable fractures, proposing an easily accessible solution available in any orthopedic operating room. It is further distinguished by its extended follow-up period (21 months) and by providing evidence of the long-term tolerability of cemented spacers - an aspect that has been infrequently reported.

American Journal of Case ReportsVol. 26
National Rehabilitation Center (KR)
Sustainable cities and communities
Openalex Percentile: Top 71%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Temporary Cemented Spacer for Complex Radial Head Fractures: A Case Report — M. A. González León, César Alejandro Jiménez-Aroche, et al. · American Journal of Case Reports (2025) | TGRS Research Map | TGRS