Measuring the Luminance Contrast Sensitivity Function in Peripheral Vision

ABSTRACT We measured luminance contrast sensitivity functions (CSF) of four subjects by using Gabor stimuli up to 56°, 49°, 84°, and 63° in the nasal, superior, temporal, and inferior directions, respectively, of the left‐eye visual field. The present measured data covered a broader range of eccentricity than those in the previous studies. The findings of this study align with previous research in terms of anisotropy in eccentricity directions. In addition, these reveal an intriguing pattern: a slight decrease in contrast sensitivity with increasing eccentricity at near eccentricity, followed by a rapid decline at eccentricity and low spatial frequency. This pattern is not predicted by 10 CSF models proposed by previous studies based on measurements in narrow eccentricity ranges. Those CSF models showed higher sensitivities at far eccentricity in comparison with our measured data. This discrepancy suggests that the CSF models with a single term for eccentricity proposed by previous studies were insufficient to fit measured data up to far eccentricities.

Authors

Institutions

Publication Details

Journal
Color Research & Application
Published
2025-08-19
DOI
https://doi.org/10.1002/col.70007
Primary Topic
Visual perception and processing mechanisms
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measuring the Luminance Contrast Sensitivity Function in Peripheral Vision

Suguru Saito, Kotaro Kitakami, Keiji Uchikawa
Color Research & Application
Visual perception and processing mechanisms
article

Measuring the Luminance Contrast Sensitivity Function in Peripheral Vision

Suguru Saito, Kotaro Kitakami, Keiji Uchikawa
article en

Abstract

ABSTRACT We measured luminance contrast sensitivity functions (CSF) of four subjects by using Gabor stimuli up to 56°, 49°, 84°, and 63° in the nasal, superior, temporal, and inferior directions, respectively, of the left‐eye visual field. The present measured data covered a broader range of eccentricity than those in the previous studies. The findings of this study align with previous research in terms of anisotropy in eccentricity directions. In addition, these reveal an intriguing pattern: a slight decrease in contrast sensitivity with increasing eccentricity at near eccentricity, followed by a rapid decline at eccentricity and low spatial frequency. This pattern is not predicted by 10 CSF models proposed by previous studies based on measurements in narrow eccentricity ranges. Those CSF models showed higher sensitivities at far eccentricity in comparison with our measured data. This discrepancy suggests that the CSF models with a single term for eccentricity proposed by previous studies were insufficient to fit measured data up to far eccentricities.

Color Research & ApplicationVol. 51(1)
Kanagawa Institute of Technology (JP), Tokyo Institute of Psychiatry (JP), Institute of Science Tokyo (JP)
Ministry of Education, Culture, Sports, Science and Technology, Japan Society for the Promotion of Science
Openalex Percentile: Top 79%
Visual perception and processing mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Measuring the Luminance Contrast Sensitivity Function in Peripheral Vision — Suguru Saito, Kotaro Kitakami, et al. · Color Research & Application (2025) | TGRS Research Map | TGRS