Reliability of an Ultrasonographic Automated Length Measurement System in Assessing Medial Elbow Joint Space

Objective: The aim of this study was to clarify the reliability of measuring the medial elbow joint space (MEJS) using an automated length measurement system (ALMS), utilizing sonography. Materials and Methods: A series of sonographic videos were captured of the MEJS. These were recorded during the transition from a resting state to a valgus stress condition, in 44 young male asymptomatic baseball players (N = 88 elbows). Two evaluators conducted the measurements using both the ALMS and manual methods to assess interrater reliability of each approach. Results: The interrater reliability of the ALMS ranged from good to excellent (intraclass correlation coefficient [ICC] 2.1, 0.83–0.98), while that of manual measurements ranged from low to excellent (ICC 2.1, 0.47–0.95). There were no significant differences in the absolute values of maximum and minimum distances of MEJS and the gap between an ALMS and manual measurements. Conclusion: Measurement of the MEJS in this cohort of young baseball players, the ALMS, based on the sonogram, demonstrated superior interrater reliability compared with manual measurements.

Authors

Institutions

Publication Details

Journal
Journal of diagnostic medical sonography
Published
2025-08-15
DOI
https://doi.org/10.1177/87564793251358272
Primary Topic
Elbow and Forearm Trauma Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability of an Ultrasonographic Automated Length Measurement System in Assessing Medial Elbow Joint Space

Yuto Uchida, Kazumasa Miida, Naonobu Takahira, Tomonori Kenmoku et al.
Journal of diagnostic medical sonography
Elbow and Forearm Trauma Treatment
article

Reliability of an Ultrasonographic Automated Length Measurement System in Assessing Medial Elbow Joint Space

Yuto Uchida, Kazumasa Miida, Naonobu Takahira, Tomonori Kenmoku, Sohei Shimizu, Masashi Kawabata, Hiroyoshi Masuma, Hiroyuki Watanabe, Yuto Sano, Koji Saito, Kazuya Takagi
article en

Abstract

Objective: The aim of this study was to clarify the reliability of measuring the medial elbow joint space (MEJS) using an automated length measurement system (ALMS), utilizing sonography. Materials and Methods: A series of sonographic videos were captured of the MEJS. These were recorded during the transition from a resting state to a valgus stress condition, in 44 young male asymptomatic baseball players (N = 88 elbows). Two evaluators conducted the measurements using both the ALMS and manual methods to assess interrater reliability of each approach. Results: The interrater reliability of the ALMS ranged from good to excellent (intraclass correlation coefficient [ICC] 2.1, 0.83–0.98), while that of manual measurements ranged from low to excellent (ICC 2.1, 0.47–0.95). There were no significant differences in the absolute values of maximum and minimum distances of MEJS and the gap between an ALMS and manual measurements. Conclusion: Measurement of the MEJS in this cohort of young baseball players, the ALMS, based on the sonogram, demonstrated superior interrater reliability compared with manual measurements.

Journal of diagnostic medical sonographyVol. 42(2)
Kitasato University Hospital (JP), National Sagamihara Hospital (JP), Konica Minolta (Japan) (JP), Kitasato University (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 74%
Elbow and Forearm Trauma Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.