Screening of Blood Serum Samples With Elevated Creatinine Levels From Renal Failure Patients Employing SERS Along With Multivariate Data Analysis Techniques

ABSTRACT Renal failure (RF) is a progressive disorder characterized by incurability, elevated morbidity, and increased mortality, frequently affecting the adult population, particularly individuals diagnosed with diabetes and hypertension. In this paper, a rapid, easy, and non‐invasive diagnostic technique, surface‐enhanced Raman spectroscopy (SERS), is discussed for the screening of RF using blood serum samples with elevated creatinine concentrations. Silver nanoparticles (AgNPs) were employed as SERS substrates to enhance the Raman signals of biomolecules present in the serum samples. For this purpose, serum samples from healthy/control individuals and RF patients with varying creatinine concentrations were used for SERS spectral measurements. The diagnostic capability of SERS was further improved by applying multivariate analysis techniques such as principal component analysis (PCA) and partial least‐squares discriminant analysis (PLS‐DA) to evaluate the potential of SERS for differentiating and classifying healthy and RF blood serum samples. Moreover, partial least‐squares regression (PLSR) was used to predict unknown creatinine concentrations in RF serum samples, yielding coefficients of determination of 0.9395 mg/dL for calibration and 0.9561 mg/dL for prediction/validation. The associated errors included a root mean squared error of calibration (RMSEC) of 0.6977 mg/dL and a root mean squared error of prediction (RMSEP) of 0.8595 mg/dL. This study demonstrates that SERS, combined with multivariate analysis, is a valuable tool for the effective diagnosis of RF.

Authors

Institutions

Publication Details

Journal
Journal of Raman Spectroscopy
Published
2025-08-17
DOI
https://doi.org/10.1002/jrs.70038
Citations
1
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
1.63

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Screening of Blood Serum Samples With Elevated Creatinine Levels From Renal Failure Patients Employing SERS Along With Multivariate Data Analysis Techniques

Muhammad Ikram Ullah, Munawar Hussain, Abdulrahman Alshammari, Muhammad Kashif et al.
1 citations
Journal of Raman Spectroscopy
Spectroscopy Techniques in Biomedical and Chemical Research
1.63
article

Screening of Blood Serum Samples With Elevated Creatinine Levels From Renal Failure Patients Employing SERS Along With Multivariate Data Analysis Techniques

Muhammad Ikram Ullah, Munawar Hussain, Abdulrahman Alshammari, Muhammad Kashif, Abdul Aziz Abdul Raman, Rana Muhammad Sabir Tariq, Haq Nawaz, Nosheen Rashid, Norah A. Albekairi, Muhammad Irfan Majeed, Muhammad Hassan, Arslan Yousaf, Muhammad Shakeel, Aziz Fatima, Abu Bakar Salfi
article en
1 citations

Abstract

ABSTRACT Renal failure (RF) is a progressive disorder characterized by incurability, elevated morbidity, and increased mortality, frequently affecting the adult population, particularly individuals diagnosed with diabetes and hypertension. In this paper, a rapid, easy, and non‐invasive diagnostic technique, surface‐enhanced Raman spectroscopy (SERS), is discussed for the screening of RF using blood serum samples with elevated creatinine concentrations. Silver nanoparticles (AgNPs) were employed as SERS substrates to enhance the Raman signals of biomolecules present in the serum samples. For this purpose, serum samples from healthy/control individuals and RF patients with varying creatinine concentrations were used for SERS spectral measurements. The diagnostic capability of SERS was further improved by applying multivariate analysis techniques such as principal component analysis (PCA) and partial least‐squares discriminant analysis (PLS‐DA) to evaluate the potential of SERS for differentiating and classifying healthy and RF blood serum samples. Moreover, partial least‐squares regression (PLSR) was used to predict unknown creatinine concentrations in RF serum samples, yielding coefficients of determination of 0.9395 mg/dL for calibration and 0.9561 mg/dL for prediction/validation. The associated errors included a root mean squared error of calibration (RMSEC) of 0.6977 mg/dL and a root mean squared error of prediction (RMSEP) of 0.8595 mg/dL. This study demonstrates that SERS, combined with multivariate analysis, is a valuable tool for the effective diagnosis of RF.

Journal of Raman SpectroscopyVol. 57(2)
Tulane University (US), King Saud University (SA), University of Faisalabad (PK), University of Agriculture Faisalabad (PK)
King Saud University
Openalex Percentile: Top 12%
Spectroscopy Techniques in Biomedical and Chemical Research
1.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.