Highly sensitive photoacoustic gas sensor using a hyperbolic nonlinear resonator integrated with a near-concentric multipass cavity

A hyperbolic nonlinear resonator (HNR) was proposed for the first time to greatly increase the sensitivity of a photoacoustic gas sensor owing to its better acoustic resonance performance than traditional cylindrical resonators. The HNR with a small resonator diameter down to 6 mm was closely integrated into a near-concentric multipass cavity (MPC) to further enhance the signal. The MPC were positioned outside the HNR so that the mirror surfaces would not be contaminated by the vapor and particles contained in the target gas due to the direct contact. The laser was collimated at a designed incident angle and reflected 42 times within the MPC, leading to a 19-fold increase in the PA signal. The sensor was also intended for use in power transformer fault diagnosis by measuring the concentration of dissolved acetylene (C 2 H 2 ) in insulating oil. A minimum detection limit (MDL) of 10 ppb was achieved with an integration time of 100 s. The sensor demonstrated a record-low normalized noise equivalent absorption (NNEA) coefficient of 4.56 × 10 -11 cm -1 ·W/Hz 1/2 . • A hyperbolic nonlinear resonator integrated a near-concentric multipass cavity. • A highly sensitive photoacoustic gas sensor was developed for acetylene. • A record-low NNEA coefficient of 4.56 × 10 -11 cm -1 ·W/Hz 1/2 was achieved.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators B Chemical
Published
2025-08-18
DOI
https://doi.org/10.1016/j.snb.2025.138533
Citations
1
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.76

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly sensitive photoacoustic gas sensor using a hyperbolic nonlinear resonator integrated with a near-concentric multipass cavity

Ruili Zhang, Sailing He, Yaopeng Cheng
1 citations
Sensors and Actuators B Chemical
Spectroscopy and Laser Applications
0.76
article

Highly sensitive photoacoustic gas sensor using a hyperbolic nonlinear resonator integrated with a near-concentric multipass cavity

Ruili Zhang, Sailing He, Yaopeng Cheng
article en
1 citations

Abstract

A hyperbolic nonlinear resonator (HNR) was proposed for the first time to greatly increase the sensitivity of a photoacoustic gas sensor owing to its better acoustic resonance performance than traditional cylindrical resonators. The HNR with a small resonator diameter down to 6 mm was closely integrated into a near-concentric multipass cavity (MPC) to further enhance the signal. The MPC were positioned outside the HNR so that the mirror surfaces would not be contaminated by the vapor and particles contained in the target gas due to the direct contact. The laser was collimated at a designed incident angle and reflected 42 times within the MPC, leading to a 19-fold increase in the PA signal. The sensor was also intended for use in power transformer fault diagnosis by measuring the concentration of dissolved acetylene (C 2 H 2 ) in insulating oil. A minimum detection limit (MDL) of 10 ppb was achieved with an integration time of 100 s. The sensor demonstrated a record-low normalized noise equivalent absorption (NNEA) coefficient of 4.56 × 10 -11 cm -1 ·W/Hz 1/2 . • A hyperbolic nonlinear resonator integrated a near-concentric multipass cavity. • A highly sensitive photoacoustic gas sensor was developed for acetylene. • A record-low NNEA coefficient of 4.56 × 10 -11 cm -1 ·W/Hz 1/2 was achieved.

Sensors and Actuators B ChemicalVol. 444
Wenzhou Medical University (CN), Electro Optical Systems (Germany) (DE), Zhejiang Taizhou Hospital (CN), Zhejiang University (CN), KTH Royal Institute of Technology (SE)
National Natural Science Foundation of China, Ningbo Municipal Bureau of Science and Technology, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 27%
Spectroscopy and Laser Applications
0.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.