A Low Cost Electrosurgery Unit (ESU) Design with Monopolar and Bipolar Methods

Surgery using a conventional scalpel causes the patient to lose a lot of blood; this needs to be avoided. The purpose of this research is to make a replacement for the conventional scalpel using a device that utilizes high frequency with a duty cycle setting that is centered at one point. The design of the device is equipped with monopolar and bipolar pulse selection with an increased frequency at 400 kHz, where the duty cycle of bipolar mode can be set to 100% on and the coagulation duty cycle is 6% on and 94% off. The power output of the module was tested using an ESU Analyzer, while cutting the bipolar forceps used soap and meat media. The power inverter circuit was set with the module impedance values ​​of 300Ω, 400Ω, and 500Ω. Power settings were set at high, medium, and low with 2 pulse cutting and coagulation modes. The average power resulted in the lowest power of 32.3Watt and the highest power cutting mode of 58.3Watt. Meanwhile, in the coagulation mode of the lowest power of 3Watt and the highest power of 3Watt, the impedance setting is 500Ω. The module can output power linearly according to settings and can cut media well. Furthermore, the development of making Electrosurgery design in this study is expected to facilitate the surgical process during the surgical procedures.

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Published
2025-08-17
DOI
https://doi.org/10.35882/ijeeemi.v4i2.147
Primary Topic
Thyroid and Parathyroid Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Low Cost Electrosurgery Unit (ESU) Design with Monopolar and Bipolar Methods

Ade Ryan Endarta, Madeha Ishag Adam, Hafsa Aamir, Levana Forra Wakidi et al.
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Thyroid and Parathyroid Surgery
article

A Low Cost Electrosurgery Unit (ESU) Design with Monopolar and Bipolar Methods

Ade Ryan Endarta, Madeha Ishag Adam, Hafsa Aamir, Levana Forra Wakidi, Bambang Guruh Irianto
article en

Abstract

Surgery using a conventional scalpel causes the patient to lose a lot of blood; this needs to be avoided. The purpose of this research is to make a replacement for the conventional scalpel using a device that utilizes high frequency with a duty cycle setting that is centered at one point. The design of the device is equipped with monopolar and bipolar pulse selection with an increased frequency at 400 kHz, where the duty cycle of bipolar mode can be set to 100% on and the coagulation duty cycle is 6% on and 94% off. The power output of the module was tested using an ESU Analyzer, while cutting the bipolar forceps used soap and meat media. The power inverter circuit was set with the module impedance values ​​of 300Ω, 400Ω, and 500Ω. Power settings were set at high, medium, and low with 2 pulse cutting and coagulation modes. The average power resulted in the lowest power of 32.3Watt and the highest power cutting mode of 58.3Watt. Meanwhile, in the coagulation mode of the lowest power of 3Watt and the highest power of 3Watt, the impedance setting is 500Ω. The module can output power linearly according to settings and can cut media well. Furthermore, the development of making Electrosurgery design in this study is expected to facilitate the surgical process during the surgical procedures.

Indonesian Journal of Electronics Electromedical Engineering and Medical InformaticsVol. 4(2)
Fujian Medical University (CN), Shaheed Zulfiqar Ali Bhutto Institute of Science and Technology (PK), Politeknik Kesehatan Kemenkes Semarang (ID), Eskom (South Africa) (ZA)
Openalex Percentile: Top 65%
Thyroid and Parathyroid Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Low Cost Electrosurgery Unit (ESU) Design with Monopolar and Bipolar Methods — Ade Ryan Endarta, Madeha Ishag Adam, et al. · Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics (2025) | TGRS Research Map | TGRS