Enhancing Infusion Pump Calibration through Evaluating Occlusion Sensor Performance in a Dual-Channel Infusion Device Analyzer

Occlusions frequently hinder the continuous delivery of medications or fluids through syringes and infusion pumps, posing a critical challenge in medical practice. To address this issue, the infusion set occlusion threshold has been established at 20 Psi, guided by ECRI standards. Annual recalibration is essential to ensure compliance with this benchmark. This study focuses on appraising the precision of a pressure sensor integrated into a dual-channel TFT display infusion device analyzer. The innovative dual-channel design streamlines the concurrent calibration of two medical instruments, enhancing efficiency. The research employs a water pressure sensor to detect occlusions and a solenoid valve to simulate pressure conditions. Upon pressure detection, the sensor transmits data to an Arduino for processing. Results are vividly displayed on a 7-inch TFT LCD screen, providing real-time graphical and numerical insights, which are also stored on an SD card. Significant findings reveal distinct error margins across devices: 2.84% for the Terumo TE-331 Infusion Pump, 7.26% for the TOP-5300 Infusion Pump, a notable 58.20% for the TOP-3300 Infusion Pump, and a striking 71.26% for the Infusia VP7 infusion, indicative of pressure accuracy variations. Notably, the SEN0257 sensor exhibits superior precision when integrated with a syringe pump, showcasing a more favorable error rate compared to larger infusion pumps. This study's implications extend to the critical domain of infusion pump calibration, offering a valuable reference for assessing device suitability. The research contributes not only to refining infusion accuracy but also offers a practical framework for optimizing medical device performance, thus enhancing the overall quality of patient care.

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Published
2025-08-17
DOI
https://doi.org/10.35882/ijeeemi.v5i3.178
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Infusion Pump Calibration through Evaluating Occlusion Sensor Performance in a Dual-Channel Infusion Device Analyzer

Triana Rahmawati, Endro Yulianto, Ach Jiddan Asrori’
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Sensor Technology and Measurement Systems
article

Enhancing Infusion Pump Calibration through Evaluating Occlusion Sensor Performance in a Dual-Channel Infusion Device Analyzer

Triana Rahmawati, Endro Yulianto, Ach Jiddan Asrori’
article en

Abstract

Occlusions frequently hinder the continuous delivery of medications or fluids through syringes and infusion pumps, posing a critical challenge in medical practice. To address this issue, the infusion set occlusion threshold has been established at 20 Psi, guided by ECRI standards. Annual recalibration is essential to ensure compliance with this benchmark. This study focuses on appraising the precision of a pressure sensor integrated into a dual-channel TFT display infusion device analyzer. The innovative dual-channel design streamlines the concurrent calibration of two medical instruments, enhancing efficiency. The research employs a water pressure sensor to detect occlusions and a solenoid valve to simulate pressure conditions. Upon pressure detection, the sensor transmits data to an Arduino for processing. Results are vividly displayed on a 7-inch TFT LCD screen, providing real-time graphical and numerical insights, which are also stored on an SD card. Significant findings reveal distinct error margins across devices: 2.84% for the Terumo TE-331 Infusion Pump, 7.26% for the TOP-5300 Infusion Pump, a notable 58.20% for the TOP-3300 Infusion Pump, and a striking 71.26% for the Infusia VP7 infusion, indicative of pressure accuracy variations. Notably, the SEN0257 sensor exhibits superior precision when integrated with a syringe pump, showcasing a more favorable error rate compared to larger infusion pumps. This study's implications extend to the critical domain of infusion pump calibration, offering a valuable reference for assessing device suitability. The research contributes not only to refining infusion accuracy but also offers a practical framework for optimizing medical device performance, thus enhancing the overall quality of patient care.

Indonesian Journal of Electronics Electromedical Engineering and Medical InformaticsVol. 5(3)
Kementerian Kesehatan Republik Indonesia (ID)
Openalex Percentile: Top 77%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhancing Infusion Pump Calibration through Evaluating Occlusion Sensor Performance in a Dual-Channel Infusion Device Analyzer — Triana Rahmawati, Endro Yulianto, et al. · Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics (2025) | TGRS Research Map | TGRS