Electronic Stethoscope Equipped with IoT-based Remote Monitoring to Detect Disease Symptoms

Auscultation is a technique or method most often used by medical personnel in the initial examination of patients. One way to carry out this method is by using a stethoscope. However, this method has its drawbacks because the diagnosis is carried out subjectively and cannot be relied on with the accuracy to diagnose the symptoms of heart defects. Thus, the purpose of this study was to create an IoT system for electronic stethoscopes with BPM value output and make analog filters to eliminate noise interference which was a major obstacle in previous studies. The contribution of this research is to make it easier for medical users to analyze heart rate using an electronic stethoscope while at the same time being able to know the number of BPM automatically that can be monitored remotely because it used IoT system. Furthermore, the method used in this study was by using a mic condenser placed on the patient's chest to detect pressure changes. When the pressure changes, the voltage output value on the condenser mic also changes. In this case, the output from the condenser mic went in and follows the analog signal conditioning circuit. The output signal from the analog signal conditioning further entered the programmed microcontroller. Furthermore, based on the measurement conducted, the error value of BPM was obtained from the five respondents. In this case, the error value generated from respondent 1 was 0.33 BPM, the error value obtained from respondent 2 was 0.67 BPM, the error value obtained from respondent 3 was 0.5 BPM, the error value obtained from respondent 4 was 0.67, and the error value obtained from respondent 5 was 0.67 BPM. Meanwhile, the results of the statistical test obtained P-Value of more than 0.05, indicating that the resulting value did not have a significant difference.

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Published
2025-08-17
DOI
https://doi.org/10.35882/ijeeemi.v4i4.157
Citations
1
Primary Topic
Energy and Environmental Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electronic Stethoscope Equipped with IoT-based Remote Monitoring to Detect Disease Symptoms

Endang Dian Setioningsih, Sumber Sumber, Torib Hamzah, Ragimova Nazila Ali
1 citations
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Energy and Environmental Systems
article

Electronic Stethoscope Equipped with IoT-based Remote Monitoring to Detect Disease Symptoms

Endang Dian Setioningsih, Sumber Sumber, Torib Hamzah, Ragimova Nazila Ali
article en
1 citations

Abstract

Auscultation is a technique or method most often used by medical personnel in the initial examination of patients. One way to carry out this method is by using a stethoscope. However, this method has its drawbacks because the diagnosis is carried out subjectively and cannot be relied on with the accuracy to diagnose the symptoms of heart defects. Thus, the purpose of this study was to create an IoT system for electronic stethoscopes with BPM value output and make analog filters to eliminate noise interference which was a major obstacle in previous studies. The contribution of this research is to make it easier for medical users to analyze heart rate using an electronic stethoscope while at the same time being able to know the number of BPM automatically that can be monitored remotely because it used IoT system. Furthermore, the method used in this study was by using a mic condenser placed on the patient's chest to detect pressure changes. When the pressure changes, the voltage output value on the condenser mic also changes. In this case, the output from the condenser mic went in and follows the analog signal conditioning circuit. The output signal from the analog signal conditioning further entered the programmed microcontroller. Furthermore, based on the measurement conducted, the error value of BPM was obtained from the five respondents. In this case, the error value generated from respondent 1 was 0.33 BPM, the error value obtained from respondent 2 was 0.67 BPM, the error value obtained from respondent 3 was 0.5 BPM, the error value obtained from respondent 4 was 0.67, and the error value obtained from respondent 5 was 0.67 BPM. Meanwhile, the results of the statistical test obtained P-Value of more than 0.05, indicating that the resulting value did not have a significant difference.

Indonesian Journal of Electronics Electromedical Engineering and Medical InformaticsVol. 4(4)
Azerbaijan State Oil and Industry University (AZ), Politeknik Kesehatan Kemenkes Semarang (ID), Eskom (South Africa) (ZA)
Openalex Percentile: Top 78%
Energy and Environmental Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.