Analysis of the Capture Output on Flat Panel Detector using Arduino-Based BPW34 Photodiode Sensor with mA and kV Setting Parameters

The exposure factor is the factor that determines the intensity and quality of X-rays received by the patient. Exposure factors that can be controlled are tube voltage (kV), tube current (mA), irradiation time (second), and distance of the X-ray tube to the film (FFD). The purpose of this study was to capture X-rays at a relatively affordable manufacturing price and to obtain different value from the detector's capture between dark and light by utilizing the response of the BPW34 photodiode sensor. The contribution of this study is that the system can display grayscale and numerical on an 8x8 pixel matrix using the Matrix Laboratory (MATLAB) Application. This study was able to convert images taken from analog data after taking measurements on X-rays. The measurements were carried out by 2 methods, the range used was 32-63 mA with a tube voltage of 50 kV at an irradiation duration of 1 second and 50 - 70 kV with a tube current of 40 mA and an irradiation duration of 1 second. Based on the measurement results, the comparison between the Flat Panel Detector Design Tool and the Philips brand Digital Radiography obtained that the latter was able to respond to differences in dose and object thickness. The results of this study indicated that this tool could be used to capture X-rays so that the degree of blackness of the film were obtained

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Published
2025-08-17
DOI
https://doi.org/10.35882/ijeeemi.v4i3.148
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the Capture Output on Flat Panel Detector using Arduino-Based BPW34 Photodiode Sensor with mA and kV Setting Parameters

Muhammad Fajar Wahyudi, Andjar Pudji, Tri Bowo Indrato, Muhammad Ridha Mak’ruf et al.
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Sensor Technology and Measurement Systems
article

Analysis of the Capture Output on Flat Panel Detector using Arduino-Based BPW34 Photodiode Sensor with mA and kV Setting Parameters

Muhammad Fajar Wahyudi, Andjar Pudji, Tri Bowo Indrato, Muhammad Ridha Mak’ruf, Shanmuganathan Palanisamy, M. R. Amin
article en

Abstract

The exposure factor is the factor that determines the intensity and quality of X-rays received by the patient. Exposure factors that can be controlled are tube voltage (kV), tube current (mA), irradiation time (second), and distance of the X-ray tube to the film (FFD). The purpose of this study was to capture X-rays at a relatively affordable manufacturing price and to obtain different value from the detector's capture between dark and light by utilizing the response of the BPW34 photodiode sensor. The contribution of this study is that the system can display grayscale and numerical on an 8x8 pixel matrix using the Matrix Laboratory (MATLAB) Application. This study was able to convert images taken from analog data after taking measurements on X-rays. The measurements were carried out by 2 methods, the range used was 32-63 mA with a tube voltage of 50 kV at an irradiation duration of 1 second and 50 - 70 kV with a tube current of 40 mA and an irradiation duration of 1 second. Based on the measurement results, the comparison between the Flat Panel Detector Design Tool and the Philips brand Digital Radiography obtained that the latter was able to respond to differences in dose and object thickness. The results of this study indicated that this tool could be used to capture X-rays so that the degree of blackness of the film were obtained

Indonesian Journal of Electronics Electromedical Engineering and Medical InformaticsVol. 4(3)
Anna University, Chennai (IN), Politeknik Kesehatan Kemenkes Semarang (ID), Poltekkes Kemenkes Surabaya
Openalex Percentile: Top 77%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of the Capture Output on Flat Panel Detector using Arduino-Based BPW34 Photodiode Sensor with mA and kV Setting Parameters — Muhammad Fajar Wahyudi, Andjar Pudji, et al. · Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics (2025) | TGRS Research Map | TGRS