Comparison of Two Designs of Wireless Electromyography Sensor Module Using Disposable Electrodes and Dry Electrodes in a Sit to Stand Motion

Electromyography is one of the biosignals used to detect muscle signals in humans. Electromyography signals are widely used as input and are engineered to help people with disabilities or assist them in post-stroke therapy recovery. Based on this phenomenon, a lot of electromyography module sensor designs were made to support various purposes in accordance with research. The purpose of this study was to compare the electromyography sensor module using a disposable electrode and a dry electrode using a wireless serial communication system. The results of this study was based on the experiment carried out in the movement from sitting to standing. Therefore, the difference would be more visible by looking at the Mean Power (MNP) value than the mean frequency (MNF). In this case, the tests were conducted using a disposable electrode, all Bluetooth test distances, relaxed conditions with a mean power value of 0.000453, and contraction with a mean power value of 0.000494. In addition, the researchers also compared serial communication transmissions using cables in relaxed conditions with a mean power value of 0.000460 and contraction with a mean power value of 0.000496. Furthermore, trials were further conducted using dry electrodes, all Bluetooth test distances, relaxed conditions with a mean power value of 0.000455, and contraction with a mean power value of 0.000503. In this case, the researchers compared serial communication transmissions using cables in relaxed conditions with a mean power value of 0.000454 and contraction with a mean power value of 0.000499. It was concluded that the design built and analyzed using mean power (MNP), obtained results that were not much different between electromyography modules using wired and wireless serial communications. It was also obtained that the electromyography module design in this study had no problem with the information.

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Published
2025-08-17
DOI
https://doi.org/10.35882/ijeeemi.v4i4.155
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Two Designs of Wireless Electromyography Sensor Module Using Disposable Electrodes and Dry Electrodes in a Sit to Stand Motion

Made Dwi Pandya Suryanta, Levana Forra Wakidi, Wahyu Caesarendra, Farid Amrinsani et al.
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Muscle activation and electromyography studies
article

Comparison of Two Designs of Wireless Electromyography Sensor Module Using Disposable Electrodes and Dry Electrodes in a Sit to Stand Motion

Made Dwi Pandya Suryanta, Levana Forra Wakidi, Wahyu Caesarendra, Farid Amrinsani, Dessy Tri Wulandari
article en

Abstract

Electromyography is one of the biosignals used to detect muscle signals in humans. Electromyography signals are widely used as input and are engineered to help people with disabilities or assist them in post-stroke therapy recovery. Based on this phenomenon, a lot of electromyography module sensor designs were made to support various purposes in accordance with research. The purpose of this study was to compare the electromyography sensor module using a disposable electrode and a dry electrode using a wireless serial communication system. The results of this study was based on the experiment carried out in the movement from sitting to standing. Therefore, the difference would be more visible by looking at the Mean Power (MNP) value than the mean frequency (MNF). In this case, the tests were conducted using a disposable electrode, all Bluetooth test distances, relaxed conditions with a mean power value of 0.000453, and contraction with a mean power value of 0.000494. In addition, the researchers also compared serial communication transmissions using cables in relaxed conditions with a mean power value of 0.000460 and contraction with a mean power value of 0.000496. Furthermore, trials were further conducted using dry electrodes, all Bluetooth test distances, relaxed conditions with a mean power value of 0.000455, and contraction with a mean power value of 0.000503. In this case, the researchers compared serial communication transmissions using cables in relaxed conditions with a mean power value of 0.000454 and contraction with a mean power value of 0.000499. It was concluded that the design built and analyzed using mean power (MNP), obtained results that were not much different between electromyography modules using wired and wireless serial communications. It was also obtained that the electromyography module design in this study had no problem with the information.

Indonesian Journal of Electronics Electromedical Engineering and Medical InformaticsVol. 4(4)
Universiti Brunei Darussalam (BN), Poltekkes Kemenkes Surabaya
Openalex Percentile: Top 80%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.