Antenatal Care Bed For Preeclamsi Early Detection Based on Web System

One of the causes of the high maternal mortality rate is dominated by three factors, one of which is preeclampsia. Preeclampsia is a condition in which the mother experiences hypertension and changes in BMI (Body Mass Index) at the 20th week of gestation. Preeclampsia indications in pregnant women are related to examinations, namely Antenatal care (ANC). Antenatal care is one of the prenatal checks with certain standards. Pregnant women need extra antenatal supervision from health workers. Preeclampsia detection carried out in health care facilities is currently considered to be still not optimal so that there are still many cases of preeclampsia that are not handled properly. A web-based ANC test is one of the ways that services for pregnant women may be improved. To make NIBP and BMI data supplied and received by IoT media helpful for the diagnostic procedure, this study will evaluate them. Knowing the reaction of NIBP and BMI data provided and received over IoT medium is the contribution of this research. The MPX5050 sensor and Loadcell, whose output will be processed and presented on a web page, will be used in the technique to accomplish this purpose. Although the largest error value was -5.4 at the measurement point of 150 mmHg at diastole, it can be argued that the measurement findings for the NIBP parameter are plausible. Overall NIBP measures, however can be considered practicable and can be used to human measurements. Additionally, the weight parameter measurement data have an error value of 0.19328%. From this study, it can be inferred that transmitting IoT-based NIBP and BMI data has an impact on received lost data or delays. The findings from this study are expected to be developed in further research.

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Published
2025-08-17
DOI
https://doi.org/10.35882/ijeeemi.v5i3.181
Primary Topic
IoT and GPS-based Vehicle Safety Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Antenatal Care Bed For Preeclamsi Early Detection Based on Web System

Shubhrojit Misra, Andjar Pudji, Muhammad Ridha Mak’ruf, Fiqih Fahrur Ramadhan
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
IoT and GPS-based Vehicle Safety Systems
article

Antenatal Care Bed For Preeclamsi Early Detection Based on Web System

Shubhrojit Misra, Andjar Pudji, Muhammad Ridha Mak’ruf, Fiqih Fahrur Ramadhan
article en

Abstract

One of the causes of the high maternal mortality rate is dominated by three factors, one of which is preeclampsia. Preeclampsia is a condition in which the mother experiences hypertension and changes in BMI (Body Mass Index) at the 20th week of gestation. Preeclampsia indications in pregnant women are related to examinations, namely Antenatal care (ANC). Antenatal care is one of the prenatal checks with certain standards. Pregnant women need extra antenatal supervision from health workers. Preeclampsia detection carried out in health care facilities is currently considered to be still not optimal so that there are still many cases of preeclampsia that are not handled properly. A web-based ANC test is one of the ways that services for pregnant women may be improved. To make NIBP and BMI data supplied and received by IoT media helpful for the diagnostic procedure, this study will evaluate them. Knowing the reaction of NIBP and BMI data provided and received over IoT medium is the contribution of this research. The MPX5050 sensor and Loadcell, whose output will be processed and presented on a web page, will be used in the technique to accomplish this purpose. Although the largest error value was -5.4 at the measurement point of 150 mmHg at diastole, it can be argued that the measurement findings for the NIBP parameter are plausible. Overall NIBP measures, however can be considered practicable and can be used to human measurements. Additionally, the weight parameter measurement data have an error value of 0.19328%. From this study, it can be inferred that transmitting IoT-based NIBP and BMI data has an impact on received lost data or delays. The findings from this study are expected to be developed in further research.

Indonesian Journal of Electronics Electromedical Engineering and Medical InformaticsVol. 5(3)
Jadavpur University (IN), Poltekkes Kemenkes Surabaya
Openalex Percentile: Top 79%
IoT and GPS-based Vehicle Safety Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.