Central Monitor Based On Personal Computer Using Single Wireless Receiver

Central monitor is a tool that monitors the patient's condition with several devices into one display on a personal computer (PC). Pulse Oximetry serves to monitor the state of oxygen saturation in the patient's blood without going through blood gas analysis. This tool uses a wireless delivery system, HC-11 that can transmit data as far as 10 meters without obstruction. This tool uses a finger sensor, an analog signal conditioner and a microcontroller that is processed to produce a percentage value of SpO2 which is then sent through HC-11. The workings of this tool are very simple by entering the finger sensor on the finger and then it will be detected by the finger sensor that will be displayed on the PC. Digital data from the ADC Atmega is received by the personal computer (PC) via Bluetooth HC-011. Furthermore, the data is processed with the Delphi program and displayed on the monitor. Appears on the Delphi application. After measurement, get an error in the SpO2 parameter, the biggest error is 1.02% and get the smallest error 0.8%.

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Published
2025-08-17
DOI
https://doi.org/10.35882/ijeeemi.v1i1.242
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Central Monitor Based On Personal Computer Using Single Wireless Receiver

Ahmad Zainul Fanani
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Sensor Technology and Measurement Systems
article

Central Monitor Based On Personal Computer Using Single Wireless Receiver

Ahmad Zainul Fanani
article en

Abstract

Central monitor is a tool that monitors the patient's condition with several devices into one display on a personal computer (PC). Pulse Oximetry serves to monitor the state of oxygen saturation in the patient's blood without going through blood gas analysis. This tool uses a wireless delivery system, HC-11 that can transmit data as far as 10 meters without obstruction. This tool uses a finger sensor, an analog signal conditioner and a microcontroller that is processed to produce a percentage value of SpO2 which is then sent through HC-11. The workings of this tool are very simple by entering the finger sensor on the finger and then it will be detected by the finger sensor that will be displayed on the PC. Digital data from the ADC Atmega is received by the personal computer (PC) via Bluetooth HC-011. Furthermore, the data is processed with the Delphi program and displayed on the monitor. Appears on the Delphi application. After measurement, get an error in the SpO2 parameter, the biggest error is 1.02% and get the smallest error 0.8%.

Indonesian Journal of Electronics Electromedical Engineering and Medical InformaticsVol. 1(1)
Politeknik Kesehatan Kemenkes Semarang (ID), Eskom (South Africa) (ZA)
Openalex Percentile: Top 77%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Central Monitor Based On Personal Computer Using Single Wireless Receiver — Ahmad Zainul Fanani · Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics (2025) | TGRS Research Map | TGRS