Quantitative measurement using panretinal optical coherence tomography with three-dimensional curve distortion correction

Panretinal optical coherence tomography (PanOCT) enables rapid, widefield retinal imaging up to 140°, visualizing peripheral regions including the ora serrata. However, raw B-scan images exhibit curvature distortion, limiting quantitative accuracy. We present a curve correction method to restore geometric fidelity. Validation with a custom 3D-printed eye phantom showed average relative errors under 1%. Clinical comparisons with CT and ultrasound demonstrated errors of 2.78% and 5.97%, respectively. These results indicate strong agreement with standard imaging modalities and support the utility of PanOCT for accurate widefield retinal measurements in clinical and research applications.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-08-18
DOI
https://doi.org/10.1364/boe.568715
Citations
1
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative measurement using panretinal optical coherence tomography with three-dimensional curve distortion correction

Yifan Jian, Susan Ostmo, David Huang, Shuibin Ni et al.
1 citations
Biomedical Optics Express
Optical Coherence Tomography Applications
0.67
article

Quantitative measurement using panretinal optical coherence tomography with three-dimensional curve distortion correction

Yifan Jian, Susan Ostmo, David Huang, Shuibin Ni, Alison H. Skalet, Yakub A. Bayhaqi, Benjamin K. Young, J. Peter Campbell, Ringo Ng, B. Merz, John Jackson
article en
1 citations

Abstract

Panretinal optical coherence tomography (PanOCT) enables rapid, widefield retinal imaging up to 140°, visualizing peripheral regions including the ora serrata. However, raw B-scan images exhibit curvature distortion, limiting quantitative accuracy. We present a curve correction method to restore geometric fidelity. Validation with a custom 3D-printed eye phantom showed average relative errors under 1%. Clinical comparisons with CT and ultrasound demonstrated errors of 2.78% and 5.97%, respectively. These results indicate strong agreement with standard imaging modalities and support the utility of PanOCT for accurate widefield retinal measurements in clinical and research applications.

Biomedical Optics ExpressVol. 16(9)
Oregon Health & Science University (US)
Openalex Percentile: Top 28%
Optical Coherence Tomography Applications
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Quantitative measurement using panretinal optical coherence tomography with three-dimensional curve distortion correction — Yifan Jian, Susan Ostmo, et al. · Biomedical Optics Express (2025) | TGRS Research Map | TGRS