Drug-Checking with Molecularly Imprinted Polymers: Addressing Xylazine-Contaminated Fentanyl

Xylazine adulterated Fentanyl is considered one of the deadliest drug threats ever faced in the United States. However, due to the complexity of the illegal drug supply, xylazine detection in the frame of drug-checking (harm reduction) remains an unsolved challenge, one which has cost numerous lives across North America. In this work, we present two sensor platforms for detecting xylazine in drug-checking applications. Both platforms are based on molecularly imprinted polymers (MIPs) using vinyl phosphonic acid as the main monomer. By combining the MIPs with thermometric and colorimetric readouts, we achieved xylazine detection in a wide concentration range, relevant in real-world scenarios. First, the heat-transfer method (HTM) allowed xylazine detection in the low concentration range within 15 min per concentration, with a limit of detection (LoD) of 16.5 ng/mL (75 nM). Second, a dye displacement assay employing methylene blue provided rapid (<5 min), visible detection with an LoD > 76 μg/mL-five times lower than the average concentration reported for street samples. Additionally, the colorimetric sensor exhibited potential for detecting various unwanted xylazine analogues, which could potentially act as fentanyl adulterants in the future. Most importantly, the colorimetric sensor consistently detected xylazine in a highly complex, street-like fentanyl sample containing five common interferents. The synergy of the proposed sensors offers a promising alternative for centralized and on-site xylazine screening in harm reduction settings.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-08-18
DOI
https://doi.org/10.1021/acssensors.5c01931
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Drug-Checking with Molecularly Imprinted Polymers: Addressing Xylazine-Contaminated Fentanyl

Gil van Wissen, Hanne Diliën, Robin van Osch, Thomas J. Cleij et al.
ACS Sensors
Analytical chemistry methods development
article

Drug-Checking with Molecularly Imprinted Polymers: Addressing Xylazine-Contaminated Fentanyl

Gil van Wissen, Hanne Diliën, Robin van Osch, Thomas J. Cleij, Kasper Eersels, Ramiro Marroquin‐Garcia, Bart van Grinsven, Rocio Arreguin-Campos, Gabriela Goraşov
article en

Abstract

Xylazine adulterated Fentanyl is considered one of the deadliest drug threats ever faced in the United States. However, due to the complexity of the illegal drug supply, xylazine detection in the frame of drug-checking (harm reduction) remains an unsolved challenge, one which has cost numerous lives across North America. In this work, we present two sensor platforms for detecting xylazine in drug-checking applications. Both platforms are based on molecularly imprinted polymers (MIPs) using vinyl phosphonic acid as the main monomer. By combining the MIPs with thermometric and colorimetric readouts, we achieved xylazine detection in a wide concentration range, relevant in real-world scenarios. First, the heat-transfer method (HTM) allowed xylazine detection in the low concentration range within 15 min per concentration, with a limit of detection (LoD) of 16.5 ng/mL (75 nM). Second, a dye displacement assay employing methylene blue provided rapid (<5 min), visible detection with an LoD > 76 μg/mL-five times lower than the average concentration reported for street samples. Additionally, the colorimetric sensor exhibited potential for detecting various unwanted xylazine analogues, which could potentially act as fentanyl adulterants in the future. Most importantly, the colorimetric sensor consistently detected xylazine in a highly complex, street-like fentanyl sample containing five common interferents. The synergy of the proposed sensors offers a promising alternative for centralized and on-site xylazine screening in harm reduction settings.

ACS SensorsVol. 10(11)
Maastricht University (NL), Sensor Electronics (United States) (US), Zuyderland Medisch Centrum (NL)
Universiteit Maastricht
Openalex Percentile: Top 77%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.