Appropriate flexion gap evaluation for fine-tuning of medial stabilizing technique in JOURNEY II bicruciate stabilized total knee arthroplasty

Successful total knee arthroplasty (TKA) relies on proper ligament balancing with a focus on medial stability. Intra-operative evaluation of the medial flexion gap must account for the relative femur–tibia positioning after implant placement. This study investigated whether intra-operative fine-tuning of the medial gap, enabled by a simple, reproducible spacer block for precise flexion gap measurement, could achieve consistent medial gap matching in both extension and flexion. Forty-seven patients (9 men, 38 women) with knee osteoarthritis underwent JOURNEY II bicruciate stabilized TKA. A spacer block simulating post-cam engagement was designed to accurately assess the medial flexion gap. Intra-operative fine-tuning of the medial flexion gap was performed using spacer blocks and a stepless femoral cutting guide. Gaps were measured during the component trial using a tension device and at 1 year post-operatively via stress radiographs. Initially, 29% of knees exhibited a flexion–extension gap difference ≥2 ​mm after posterior cruciate ligament resection and tibial osteotomy. Spacer block fine-tuning reduced this to 8% and this improvement persisted at 1 year. At 4 years follow-up, Knee Society Scores were favorable, with significant gains in extension and flexion angles. The developed spacer block technique, which replicates the post-cam engaging position, provided consistent and accurate flexion gap measurements and reduced flexion–extension discrepancies. This approach enhanced knee stability and patient outcome post-TKA. • Novel spacer block simulates post-cam engagement for accurate flexion gap measurement. • Method enhances medial stability in JOURNEY II bicruciate stabilized total knee arthroplasty. • Technique achieved ≤2 ​mm medial flexion–extension gap matching in 92% of knees at 1 year.

Authors

Institutions

Publication Details

Journal
Journal of Joint Surgery and Research
Published
2025-08-18
DOI
https://doi.org/10.1016/j.jjoisr.2025.07.004
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Appropriate flexion gap evaluation for fine-tuning of medial stabilizing technique in JOURNEY II bicruciate stabilized total knee arthroplasty

Ichiro Kurakazu, Satoshi Hamai, Shinya Kawahara, Yukio Akasaki et al.
Journal of Joint Surgery and Research
Total Knee Arthroplasty Outcomes
article

Appropriate flexion gap evaluation for fine-tuning of medial stabilizing technique in JOURNEY II bicruciate stabilized total knee arthroplasty

Ichiro Kurakazu, Satoshi Hamai, Shinya Kawahara, Yukio Akasaki, K. Kitamura, Yasuharu Nakashima
article en

Abstract

Successful total knee arthroplasty (TKA) relies on proper ligament balancing with a focus on medial stability. Intra-operative evaluation of the medial flexion gap must account for the relative femur–tibia positioning after implant placement. This study investigated whether intra-operative fine-tuning of the medial gap, enabled by a simple, reproducible spacer block for precise flexion gap measurement, could achieve consistent medial gap matching in both extension and flexion. Forty-seven patients (9 men, 38 women) with knee osteoarthritis underwent JOURNEY II bicruciate stabilized TKA. A spacer block simulating post-cam engagement was designed to accurately assess the medial flexion gap. Intra-operative fine-tuning of the medial flexion gap was performed using spacer blocks and a stepless femoral cutting guide. Gaps were measured during the component trial using a tension device and at 1 year post-operatively via stress radiographs. Initially, 29% of knees exhibited a flexion–extension gap difference ≥2 ​mm after posterior cruciate ligament resection and tibial osteotomy. Spacer block fine-tuning reduced this to 8% and this improvement persisted at 1 year. At 4 years follow-up, Knee Society Scores were favorable, with significant gains in extension and flexion angles. The developed spacer block technique, which replicates the post-cam engaging position, provided consistent and accurate flexion gap measurements and reduced flexion–extension discrepancies. This approach enhanced knee stability and patient outcome post-TKA. • Novel spacer block simulates post-cam engagement for accurate flexion gap measurement. • Method enhances medial stability in JOURNEY II bicruciate stabilized total knee arthroplasty. • Technique achieved ≤2 ​mm medial flexion–extension gap matching in 92% of knees at 1 year.

Journal of Joint Surgery and ResearchVol. 3(3)
Kyushu University (JP)
Openalex Percentile: Top 65%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.