Numerical study on the effect of chip muffler on the thermal performance of S-NDWCT under crosswind

Abstract The chip muffler demonstrates dual functionality in cooling tower applications, serving not only as an effective noise reduction device but also exerting a significant influence on the thermal characteristics of natural draft wet cooling towers. This study investigates the aerodynamic and thermodynamic impacts of four distinct shading configurations (non-shaded, quarter-shaded, half-shaded, and three-quarter-shaded) on cooling tower performance under crosswind conditions ranging from 0 to 12 m/s. Through comprehensive three-dimensional numerical modeling of the modified muffler structure, we systematically analyzed airflow patterns, temperature distribution, and cooling efficiency enhancement mechanisms. Our findings reveal that the strategic implementation of chip mufflers can optimize airflow uniformity within the tower while effectively mitigating adverse crosswind effects. The half-shaded configuration demonstrated optimal performance, achieving a maximum cooling efficiency improvement of 4.49% at 7 m/s wind speed compared to conventional unmodified towers, accompanied by a substantial ventilation capacity increase of 1196.54 kg/s.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-08-01
DOI
https://doi.org/10.1088/1742-6596/3065/1/012060
Primary Topic
Gas Dynamics and Kinetic Theory
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical study on the effect of chip muffler on the thermal performance of S-NDWCT under crosswind

Keting He, Xiaoyu Zhang, Lei Zhang, Runchen Wang et al.
Journal of Physics Conference Series
Gas Dynamics and Kinetic Theory
article

Numerical study on the effect of chip muffler on the thermal performance of S-NDWCT under crosswind

Keting He, Xiaoyu Zhang, Lei Zhang, Runchen Wang, Zhihui Zhang
article en

Abstract

Abstract The chip muffler demonstrates dual functionality in cooling tower applications, serving not only as an effective noise reduction device but also exerting a significant influence on the thermal characteristics of natural draft wet cooling towers. This study investigates the aerodynamic and thermodynamic impacts of four distinct shading configurations (non-shaded, quarter-shaded, half-shaded, and three-quarter-shaded) on cooling tower performance under crosswind conditions ranging from 0 to 12 m/s. Through comprehensive three-dimensional numerical modeling of the modified muffler structure, we systematically analyzed airflow patterns, temperature distribution, and cooling efficiency enhancement mechanisms. Our findings reveal that the strategic implementation of chip mufflers can optimize airflow uniformity within the tower while effectively mitigating adverse crosswind effects. The half-shaded configuration demonstrated optimal performance, achieving a maximum cooling efficiency improvement of 4.49% at 7 m/s wind speed compared to conventional unmodified towers, accompanied by a substantial ventilation capacity increase of 1196.54 kg/s.

Journal of Physics Conference SeriesVol. 3065(1)
Shenyang Institute of Engineering (CN), University of Jinan (CN)
Openalex Percentile: Top 69%
Gas Dynamics and Kinetic Theory
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.