Daylighting Performance Simulation and Optimization Design of a “Campus Living Room” Based on BIM Technology—A Case Study in a Region with Hot Summers and Cold Winters

In the context of green building development, the lighting design of campus living rooms in hot summer and cold winter areas faces the dual challenges of glare control in summer and insufficient daylight in winter. Based on BIM technology, this study uses Revit 2016 modeling and the HYBPA 2024 performance analysis platform to simulate and optimize the daylighting performance of the campus activity center of Hunan City College in multiple rounds of iterations. It is found that the traditional single large-area external window design leads to uneven lighting in 70% of the area, and the average value of the lighting coefficient is only 2.1%, which is lower than the national standard requirement of 3.3%. Through the introduction of the hybrid system of “side lighting + top light guide”, combined with adjustable inner louver shading, the optimized average value of the lighting coefficient is increased to 4.8%, the uniformity of indoor illuminance is increased from 0.35 to 0.68, the proportion of annual standard sunshine hours (≥300 lx) reaches 68.7%, and the energy consumption of the artificial lighting is reduced by 27.3%. Dynamic simulation shows that the uncomfortable glare index at noon on the summer solstice is reduced from 30.2 to 22.7, which meets the visual comfort requirements. The study confirms that the BIM-driven “static-dynamic” simulation coupling method can effectively address climate adaptability issues. However, it has limitations such as insufficient integration with international healthy building standards, insufficient accuracy of meteorological data, and simplification of indoor dynamic shading factors. Future research can focus on improving meteorological data accuracy, incorporating indoor dynamic factors, and exploring intelligent daylighting systems to deepen and expand the method, promote the integration of cross-standard evaluation systems, and provide a technical pathway for healthy lighting environment design in summer-hot and winter-cold regions.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-08-16
DOI
https://doi.org/10.3390/buildings15162904
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Daylighting Performance Simulation and Optimization Design of a “Campus Living Room” Based on BIM Technology—A Case Study in a Region with Hot Summers and Cold Winters

Qing Zeng, Guangyu Ou
1 links
Buildings
Building Energy and Comfort Optimization
article

Daylighting Performance Simulation and Optimization Design of a “Campus Living Room” Based on BIM Technology—A Case Study in a Region with Hot Summers and Cold Winters

Qing Zeng, Guangyu Ou
article en

Abstract

In the context of green building development, the lighting design of campus living rooms in hot summer and cold winter areas faces the dual challenges of glare control in summer and insufficient daylight in winter. Based on BIM technology, this study uses Revit 2016 modeling and the HYBPA 2024 performance analysis platform to simulate and optimize the daylighting performance of the campus activity center of Hunan City College in multiple rounds of iterations. It is found that the traditional single large-area external window design leads to uneven lighting in 70% of the area, and the average value of the lighting coefficient is only 2.1%, which is lower than the national standard requirement of 3.3%. Through the introduction of the hybrid system of “side lighting + top light guide”, combined with adjustable inner louver shading, the optimized average value of the lighting coefficient is increased to 4.8%, the uniformity of indoor illuminance is increased from 0.35 to 0.68, the proportion of annual standard sunshine hours (≥300 lx) reaches 68.7%, and the energy consumption of the artificial lighting is reduced by 27.3%. Dynamic simulation shows that the uncomfortable glare index at noon on the summer solstice is reduced from 30.2 to 22.7, which meets the visual comfort requirements. The study confirms that the BIM-driven “static-dynamic” simulation coupling method can effectively address climate adaptability issues. However, it has limitations such as insufficient integration with international healthy building standards, insufficient accuracy of meteorological data, and simplification of indoor dynamic shading factors. Future research can focus on improving meteorological data accuracy, incorporating indoor dynamic factors, and exploring intelligent daylighting systems to deepen and expand the method, promote the integration of cross-standard evaluation systems, and provide a technical pathway for healthy lighting environment design in summer-hot and winter-cold regions.

BuildingsVol. 15(16)
Hunan City University (CN), Guangdong Urban & Rural Planning and Design Institute (CN)
Openalex Percentile: Top 78%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.