A LAP-Specific Hydrolyzable Fluorescent Probe for Assessing Combined Toxicity in Pesticide Mixtures

Addressing the lack of dynamic monitoring methods for assessing the combined toxicity of mixed pesticides, this study developed a fluorescent probe, CCHL, specifically responsive to leucine aminopeptidase (LAP). The probe utilized Cy7-COOH (CCH) as the fluorophore, with fluorescence recovery triggered by enzymatic hydrolysis. Spectral characterization confirmed a linear response between the probe and LAP activity within a concentration range of 0–0.9 μg/mL (R2 = 0.992), along with excellent selectivity in the presence of coexisting biomolecules. Application experiments demonstrated that the combination of chlorfenapyr and beta-cyfluthrin significantly reduced LAP activity, revealing a notable antagonistic effect. The novel sensing strategy developed here provides a real-time, visualized analytical tool for evaluating the combined effects of mixed pollutants, demonstrating significant potential for environmental toxicology monitoring.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2025-08-16
DOI
https://doi.org/10.3390/chemosensors13080310
Primary Topic
Pesticide and Herbicide Environmental Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A LAP-Specific Hydrolyzable Fluorescent Probe for Assessing Combined Toxicity in Pesticide Mixtures

Jingnan Cui, Ming Zhang, Yan Gao, Xin Zhao et al.
Chemosensors
Pesticide and Herbicide Environmental Studies
article

A LAP-Specific Hydrolyzable Fluorescent Probe for Assessing Combined Toxicity in Pesticide Mixtures

Jingnan Cui, Ming Zhang, Yan Gao, Xin Zhao, Zhihao Xu
article en

Abstract

Addressing the lack of dynamic monitoring methods for assessing the combined toxicity of mixed pesticides, this study developed a fluorescent probe, CCHL, specifically responsive to leucine aminopeptidase (LAP). The probe utilized Cy7-COOH (CCH) as the fluorophore, with fluorescence recovery triggered by enzymatic hydrolysis. Spectral characterization confirmed a linear response between the probe and LAP activity within a concentration range of 0–0.9 μg/mL (R2 = 0.992), along with excellent selectivity in the presence of coexisting biomolecules. Application experiments demonstrated that the combination of chlorfenapyr and beta-cyfluthrin significantly reduced LAP activity, revealing a notable antagonistic effect. The novel sensing strategy developed here provides a real-time, visualized analytical tool for evaluating the combined effects of mixed pollutants, demonstrating significant potential for environmental toxicology monitoring.

ChemosensorsVol. 13(8)
Dalian University of Technology (CN), Dalian University (CN)
National Key Research and Development Program of China
Openalex Percentile: Top 84%
Pesticide and Herbicide Environmental Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A LAP-Specific Hydrolyzable Fluorescent Probe for Assessing Combined Toxicity in Pesticide Mixtures — Jingnan Cui, Ming Zhang, et al. · Chemosensors (2025) | TGRS Research Map | TGRS