Determination of the Permanganate Index in High-Chlorine Water Bodies

Despite the significant demand, accurate determination of the permanganate index in high-chloride bodies of water remains extremely limited. This study introduces an iodine-thiosulfate method that effectively eliminates the interference of chloride ions in the permanganate index determination. In this method, organic and inorganic substances in a water sample are oxidized with KMnO4 in an alkaline medium to mitigate chloride ion interference. To further minimize this interference during back-titration, the remaining KMnO4 is reduced using KI under adjusted acidic conditions. The released iodine is then titrated with standardized Na2S2O3 until the starch–iodine complex’s blue–black color disappears. The iodine-thiosulfate method demonstrated a method detection limit of 0.4 mg L–1 (n = 7) and a corresponding interlaboratory quantification limit of 1.6 mg L–1 in water samples with chloride concentrations of 5000 mg L–1. The method’s precision and accuracy ranged from 1.4% to 6.7% and −1.0% to 5.0%, respectively. The relative error in permanganate index determination remained below 20% even at chloride concentrations up to 60 g L–1, whereas the conventional oxalate-permanganate method exceeded a 20% relative error once the chloride concentration reached 10 g L–1 or higher. The sufficiently low detection limit along with excellent repeatability (intralaboratory precision), reproducibility (interlaboratory precision), and accuracy confirms its practical feasibility for routine analysis.

Authors

Institutions

Publication Details

Journal
ACS ES&T Water
Published
2025-08-18
DOI
https://doi.org/10.1021/acsestwater.5c00498
Primary Topic
Water Quality Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of the Permanganate Index in High-Chlorine Water Bodies

Zhengke Li, Shu-Wei Pei, Xiaohong Zhou, Jingjing Guo et al.
ACS ES&T Water
Water Quality Monitoring and Analysis
article

Determination of the Permanganate Index in High-Chlorine Water Bodies

Zhengke Li, Shu-Wei Pei, Xiaohong Zhou, Jingjing Guo, Ruozhen Yu, Yu Zhang, Lin Wang, Jinhong Li, Yalcun Turlana
article en

Abstract

Despite the significant demand, accurate determination of the permanganate index in high-chloride bodies of water remains extremely limited. This study introduces an iodine-thiosulfate method that effectively eliminates the interference of chloride ions in the permanganate index determination. In this method, organic and inorganic substances in a water sample are oxidized with KMnO4 in an alkaline medium to mitigate chloride ion interference. To further minimize this interference during back-titration, the remaining KMnO4 is reduced using KI under adjusted acidic conditions. The released iodine is then titrated with standardized Na2S2O3 until the starch–iodine complex’s blue–black color disappears. The iodine-thiosulfate method demonstrated a method detection limit of 0.4 mg L–1 (n = 7) and a corresponding interlaboratory quantification limit of 1.6 mg L–1 in water samples with chloride concentrations of 5000 mg L–1. The method’s precision and accuracy ranged from 1.4% to 6.7% and −1.0% to 5.0%, respectively. The relative error in permanganate index determination remained below 20% even at chloride concentrations up to 60 g L–1, whereas the conventional oxalate-permanganate method exceeded a 20% relative error once the chloride concentration reached 10 g L–1 or higher. The sufficiently low detection limit along with excellent repeatability (intralaboratory precision), reproducibility (interlaboratory precision), and accuracy confirms its practical feasibility for routine analysis.

ACS ES&T WaterVol. 5(9)
Qinghai University (CN), Qinghai No.3 People's Hospital (CN), Beijing Municipal Ecological and Environmental Monitoring Center (CN), Qinghai Meteorological Institute (CN), Qinghai Meteorological Bureau (CN), Chinese Research Academy of Environmental Sciences (CN), Tsinghua University (CN)
Ministry of Ecology and Environment, The People’s Republic of China
Clean water and sanitation
Openalex Percentile: Top 74%
Water Quality Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.