Effects of ventilator tubing corrugation design on condensate accumulation

Abstract Background The use of adequately humidified and heated gas during invasive mechanical ventilation (IMV) is mandatory to prevent complications associated with under humidification. However, condensate formation within ventilator tubing remains a persistent challenge that can compromise ventilation efficiency and patient safety. This study investigates whether the shape of ventilator tubing influences the formation of condensate, focusing on its implications for both non-invasive ventilation (NIV) and IMV. Methods A commercially available adult heated tubing was used as a control group(conventional heated tubing) alongside nine experimental tubing designs with distinct combinations of corrugation angle (non-skewed, left-skewed, right-skewed) and wavelength (narrow, standard, wide). The tubing sets were connected to a heated humidifier, and condensate accumulation was measured at 1, 2, 4, 8, and 24 h under controlled environmental conditions (23 °C–26 °C, relative humidity 40–60%). Data were averaged across three trials, and a two-way analysis of variance (ANOVA) was conducted to assess the effects of design variables. Results By 8 h, inter-tube differences reached 11.8 g, increasing to 42.8 g by 24 h. Two-way ANOVA revealed that wavelength significantly affected condensate buildup (p = 0.016), while skew angle did not (p = 0.126). However, their interaction was significant (p = 0.012). WN showed the highest 24-h condensate accumulation (265.07 ± 6.99 g), whereas SR had the lowest (222.27 ± 22.55 g), outperforming the control (SN: 238.83 ± 4.39 g). Conclusion These findings underscore the pivotal influence of wavelength on condensate formation. Compared with the conventional SN design, SR reduced 24-h condensate by approximately 16.56 g (~ 7%). Tailoring tubing designs based on wavelength and skew angle can help optimize mechanical ventilation performance and potentially enhance patient safety and comfort by reducing condensate-related complications.

Authors

Institutions

Publication Details

Journal
Discover Applied Sciences
Published
2025-08-18
DOI
https://doi.org/10.1007/s42452-025-07060-8
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of ventilator tubing corrugation design on condensate accumulation

Ding‐Yang Hsu
5 links
Discover Applied Sciences
Respiratory Support and Mechanisms
article

Effects of ventilator tubing corrugation design on condensate accumulation

Ding‐Yang Hsu
article en

Abstract

Abstract Background The use of adequately humidified and heated gas during invasive mechanical ventilation (IMV) is mandatory to prevent complications associated with under humidification. However, condensate formation within ventilator tubing remains a persistent challenge that can compromise ventilation efficiency and patient safety. This study investigates whether the shape of ventilator tubing influences the formation of condensate, focusing on its implications for both non-invasive ventilation (NIV) and IMV. Methods A commercially available adult heated tubing was used as a control group(conventional heated tubing) alongside nine experimental tubing designs with distinct combinations of corrugation angle (non-skewed, left-skewed, right-skewed) and wavelength (narrow, standard, wide). The tubing sets were connected to a heated humidifier, and condensate accumulation was measured at 1, 2, 4, 8, and 24 h under controlled environmental conditions (23 °C–26 °C, relative humidity 40–60%). Data were averaged across three trials, and a two-way analysis of variance (ANOVA) was conducted to assess the effects of design variables. Results By 8 h, inter-tube differences reached 11.8 g, increasing to 42.8 g by 24 h. Two-way ANOVA revealed that wavelength significantly affected condensate buildup (p = 0.016), while skew angle did not (p = 0.126). However, their interaction was significant (p = 0.012). WN showed the highest 24-h condensate accumulation (265.07 ± 6.99 g), whereas SR had the lowest (222.27 ± 22.55 g), outperforming the control (SN: 238.83 ± 4.39 g). Conclusion These findings underscore the pivotal influence of wavelength on condensate formation. Compared with the conventional SN design, SR reduced 24-h condensate by approximately 16.56 g (~ 7%). Tailoring tubing designs based on wavelength and skew angle can help optimize mechanical ventilation performance and potentially enhance patient safety and comfort by reducing condensate-related complications.

Discover Applied SciencesVol. 7(9)
Ming Chi University of Technology (TW)
Openalex Percentile: Top 68%
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effects of ventilator tubing corrugation design on condensate accumulation — Ding‐Yang Hsu · Discover Applied Sciences (2025) | TGRS Research Map | TGRS