Challenges in Temperature Measurement in Hot Forging Processes: Impact of Measurement Method Selection on Accuracy and Errors in the Context of Tool Life and Forging Quality

This study investigates the influence of temperature measurement accuracy on tool failure mechanisms in industrial hot forging processes. Challenges related to extreme operational conditions, including high temperatures, limited access to measurement surfaces, and optical interferences, significantly hinder reliable data acquisition. Thermal imaging, pyrometry, thermocouples, and finite element modeling were employed to characterize temperature distributions in forging tools and billets. Analysis of multi-stage forging of stainless steel valve forgings revealed significant discrepancies between induction heater settings and actual billet surface temperatures, measured by thermal imaging. This thermal non-uniformity led to localized underheating and insufficient dissolution of hard inclusions, confirmed by dilatometric tests, resulting in billet jamming and premature tool failure. In slender bolt-type forgings, excessive or improperly controlled billet temperatures increased adhesion between the forging and tool surface, causing process resistance, billet sticking, and accelerated tool degradation. Additional challenges were noted in tool preheating, where non-uniform heating and inaccurate temperature assessment compromised early tool performance. Measurement errors associated with thermal imaging, particularly due to thermal reflections in robotic gripper monitoring, led to overestimated temperatures and overheating of gripping elements, impairing forging manipulation accuracy. The results emphasize that effective temperature measurement management, including cross-validation of methods, is crucial for assessing tool condition, enhancing process reliability, and preventing premature failures in hot forging operations.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-08-17
DOI
https://doi.org/10.3390/ma18163850
Primary Topic
Metallurgy and Material Forming
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Challenges in Temperature Measurement in Hot Forging Processes: Impact of Measurement Method Selection on Accuracy and Errors in the Context of Tool Life and Forging Quality

Łukasz Dudkiewicz, Marta Janik, Jakub Krawczyk, Mateusz Skwarski et al.
Materials
Metallurgy and Material Forming
article

Challenges in Temperature Measurement in Hot Forging Processes: Impact of Measurement Method Selection on Accuracy and Errors in the Context of Tool Life and Forging Quality

Łukasz Dudkiewicz, Marta Janik, Jakub Krawczyk, Mateusz Skwarski, Marzena Lachowicz, Marek Hawryluk
article en

Abstract

This study investigates the influence of temperature measurement accuracy on tool failure mechanisms in industrial hot forging processes. Challenges related to extreme operational conditions, including high temperatures, limited access to measurement surfaces, and optical interferences, significantly hinder reliable data acquisition. Thermal imaging, pyrometry, thermocouples, and finite element modeling were employed to characterize temperature distributions in forging tools and billets. Analysis of multi-stage forging of stainless steel valve forgings revealed significant discrepancies between induction heater settings and actual billet surface temperatures, measured by thermal imaging. This thermal non-uniformity led to localized underheating and insufficient dissolution of hard inclusions, confirmed by dilatometric tests, resulting in billet jamming and premature tool failure. In slender bolt-type forgings, excessive or improperly controlled billet temperatures increased adhesion between the forging and tool surface, causing process resistance, billet sticking, and accelerated tool degradation. Additional challenges were noted in tool preheating, where non-uniform heating and inaccurate temperature assessment compromised early tool performance. Measurement errors associated with thermal imaging, particularly due to thermal reflections in robotic gripper monitoring, led to overestimated temperatures and overheating of gripping elements, impairing forging manipulation accuracy. The results emphasize that effective temperature measurement management, including cross-validation of methods, is crucial for assessing tool condition, enhancing process reliability, and preventing premature failures in hot forging operations.

MaterialsVol. 18(16)
Wrocław University of Science and Technology (PL), KGHM Polska Miedź (Poland) (PL), Łukasiewicz Research Network - Metal Forming Institute (PL), AGH University of Krakow (PL)
Openalex Percentile: Top 76%
Metallurgy and Material Forming
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.