Pocket Infection Leading to Complete Extrusion of an Implantable Cardiac Defibrillator

Pocket infection and complete device extrusion are uncommon but potentially life-threatening complications that present significant management challenges. Extrusion results from progressive skin erosion until the device exits the subcutaneous pocket, at which point the risk of bacterial contamination becomes high. Diagnosis of extrusion is based primarily on clinical examination, while the diagnosis of cardiac implantable electronic device (CIED) endocarditis relies on the modified Duke criteria in conjunction with multimodality imaging. Alongside echocardiography, 18F-FDG PET-CT is increasingly used for the diagnosis of endocarditis; it is particularly valuable when the diagnosis is uncertain and contributes to identifying potential portals of entry. Management depends on the extent of infection and requires bactericidal antibiotic therapy combined with complete device and lead extraction, followed by re-implantation of a new system when clinically appropriate. Early recognition of erosion signs before the device breaches the skin, along with rigorous measures to prevent pocket contamination and subsequent endocarditis, remains crucial to avoid severe complications.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-08-18
DOI
https://doi.org/10.7759/cureus.90392
Primary Topic
Infective Endocarditis Diagnosis and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pocket Infection Leading to Complete Extrusion of an Implantable Cardiac Defibrillator

Wassim Beladel, Mohamed El Minaoui, Karim Hasni, Soukaina Aabbar
Cureus
Infective Endocarditis Diagnosis and Management
article

Pocket Infection Leading to Complete Extrusion of an Implantable Cardiac Defibrillator

Wassim Beladel, Mohamed El Minaoui, Karim Hasni, Soukaina Aabbar
article en

Abstract

Pocket infection and complete device extrusion are uncommon but potentially life-threatening complications that present significant management challenges. Extrusion results from progressive skin erosion until the device exits the subcutaneous pocket, at which point the risk of bacterial contamination becomes high. Diagnosis of extrusion is based primarily on clinical examination, while the diagnosis of cardiac implantable electronic device (CIED) endocarditis relies on the modified Duke criteria in conjunction with multimodality imaging. Alongside echocardiography, 18F-FDG PET-CT is increasingly used for the diagnosis of endocarditis; it is particularly valuable when the diagnosis is uncertain and contributes to identifying potential portals of entry. Management depends on the extent of infection and requires bactericidal antibiotic therapy combined with complete device and lead extraction, followed by re-implantation of a new system when clinically appropriate. Early recognition of erosion signs before the device breaches the skin, along with rigorous measures to prevent pocket contamination and subsequent endocarditis, remains crucial to avoid severe complications.

CureusVol. 17(8)
Université de Toulon (FR), Toulon Var Technologies (France) (FR), Université Ibn Zohr (MA), Centre Hospitalier Intercommunal Toulon-La Seyne-sur-Mer (FR)
Zero hunger
Openalex Percentile: Top 71%
Infective Endocarditis Diagnosis and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Pocket Infection Leading to Complete Extrusion of an Implantable Cardiac Defibrillator — Wassim Beladel, Mohamed El Minaoui, et al. · Cureus (2025) | TGRS Research Map | TGRS