Transcatheter Tricuspid Valve Replacement Using the LuX-Valve Plus system: 1-Year Compassionate Use Outcomes

Transcatheter tricuspid valve replacement (TTVR) has emerged as an important treatment tool for patients with severe tricuspid regurgitation (TR) and heart failure.1 Currently, one TTVR device is Food and Drug Administration and CE mark approved and several others are at different stages of development. For the transjugular LuX-Valve Plus TTVR system, evidence is consistently growing. Besides compassionate use 30-day outcome data,2 the TRAVEL study recently reported effective TR reduction (≤2+ in 95.5% of patients) in an Asian patient population, while being associated with low procedural complication rates (permanent pacemaker requirement in 1.6%, severe bleeding in 14.3%) and good 1-year survival (89.7%).3 Since 1-year real-world data outside of China are lacking, the present study aimed at investigating 1-year outcomes following compassionate use LuX-Valve Plus TTVR. The study included consecutive patients from 16 international centres who underwent LuX-Valve Plus TTVR from 2019 until 2024 in a compassionate use programme. Accordingly, no pre-specified in- or exclusion criteria were available and the individual screening process was left to the discretion of each individual centre. Procedural details of TTVR using the LuX-Valve Plus system have previously been described.4 One-year endpoints included clinical success according to the Tricuspid Valve Academic Research Consortium (TVARC),5 TR reduction, 1-year survival and survival free from heart failure hospitalization (HFH), changes in New York Heart Association (NYHA) functional class and symptoms of right ventricular (RV) failure, RV reverse remodelling (RVRR) as well TTVR-related adverse events. Numbers are presented as mean ± standard deviation or median with interquartile range (IQR). Two dependent samples were compared using the Wilcoxon test. A two-sided p-value of <0.05 yielded statistical significance. All analyses were performed using R (version 4.0.4) and SPSS (version 25, IBM, Armonk, NY, USA). The analysis was approved by each centre's local ethics committee and adheres to the principles outlined in the Declaration of Helsinki. The study included a total of 74 patients (mean age 75.9 ± 7.4 years; 56.8% women). TR was severe, massive and torrential in 13.7%, 21.9% and 64.4%, respectively. Patients were highly symptomatic (NYHA class ≥III 84.3%, peripheral oedema 81.1%, ascites 40.3%, pleural effusion 35.6%) and presented with advanced surgical risk (TRI-SCORE 5.9 ± 2.4 points). Renal function was impaired as represented by an estimated glomerular filtration rate of 52.4 ± 25.2 ml/min. The median N-terminal pro-B-type natriuretic peptide value was 1985 (IQR 1023–3668) pg/ml. The most common comorbidities within the study cohort were atrial fibrillation (90.4%), arterial hypertension (62.2%) and coronary artery disease (32.9%). TTVR reduced TR to ≤1+ and ≤2+ in 90.5% and 94.6% of patients, respectively. Residual TR was paravalvular in all cases. Intraprocedural success according to TVARC was achieved in 68 patients (91.1%) with a mean procedural time of 131 ± 40 min. The postprocedural tricuspid valve inflow gradient was 2.0 ± 1.2 mmHg. Overall, 42.5% of patients were discharged with prescription of direct oral anticoagulants and 53.5% with vitamin K antagonists. Antiplatelet therapy included acetylsalicylic acid in 5.7% of patients. One-year follow-up was available in 39 out of 41 eligible patients (alive and TTVR performed >1 year ago) (Figure 1). Clinical success at 1-year follow-up was 76.9% with durable TR reduction to ≤1+ in 78.4% and ≤2+ in 86.5% of patients (p < 0.001). Residual TR was of paravalvular nature in all cases. One-year survival and survival free from HFH were 77.7% and 66.8%, respectively. At 1-year follow-up, NYHA functional class improved to ≤ II in 94.6% of patients (vs. 15.7% at baseline, p < 0.001). Beyond that, TTVR was associated with an improvement in heart failure symptoms (peripheral oedema 22.2% vs. 81.1%, ascites 0% vs. 40.3%, pleural effusion 11.1% vs. 35.6%, all p < 0.001). While 6-min walking test distance remained statistically unchanged (baseline 274 ± 119 m; 1-year follow-up 295 ± 127 m, p = 0.345), the Kansas City Cardiomyopathy Questionnaire (KCCQ) significantly improved (baseline 54.4 ± 23.5; 1-year follow-up 68.7 ± 32.5, p = 0.017). Echocardiographically, TTVR was associated with numeric RVRR (reduction in RV midventricular diameter from 43.9 ± 8.9 mm at baseline to 36.3 ± 9.7 mm at 1-year follow-up, p = 0.087) and a decrease in RV function (decrease in tricuspid annular plane systolic excursion from 17.2 ± 4.6 mm at baseline to 15.4 ± 5.5 mm at 1-year follow-up, p = 0.024; RV fractional area change from 37.3 ± 9.0% to 35.6 ± 8.0%, p = 0.249). Within the whole study period no events of myocardial infarction, stroke, pulmonary embolism, or valve thrombosis were noted. While five patients (6.7%) suffered bleeding complications within the index hospitalization, no further bleeding events were noted during follow-up. No association between bleeding complications and antiplatelet or anticoagulation therapy was observed. Among 50 pacemaker naïve individuals, three patients (6.0%) required permanent pacemaker implantation within the first 30 days after the procedure with one further patient 8 months after TTVR due to atrial fibrillation with slow ventricular response (cumulative incidence at 1 year 8.0%). In summary, this is the largest available compassionate use LuX-Valve Plus TTVR experience available today. Compared to controlled data from the recently published TRAVEL trial, 1-year survival and survival free from HFH were lower among real-world patients (78% vs. 90% and 67% vs. 85% for this study vs. TRAVEL, respectively) probably reflecting a more selected patient cohort within the trial environment.3 Beyond that, many patients within this compassionate use cohort were ineligible for alternative treatment options due to comorbidities or challenging anatomical conditions. Comparable results were observed for TR reduction to ≤2+ (87% vs. 95%). With a cumulative pacemaker implantation rate of 8.0% of pacemaker naïve patients at 1 year, numbers were higher under real-world conditions compared to trial data (1.6%). Noteworthy, those numbers are lower compared to other TTVR devices with more radial anchoring force (e.g. ~25% of pacemaker naïve patients in TRISCEND II).6 Alike reported in the TRAVEL study, TTVR using the LuX-Valve Plus system was associated with an improvement in quality of life as assessed by the KCCQ. In line with previous reports, RV function numerically declined after TTVR reflecting a pseudonormalization of RV function from a previously hyperactive state.7-9 This study is subject to a number of limitations, primarily due to the retrospective nature of the registry (no control group, no echocardiographic core laboratory or clinical event adjudication committee). However, echocardiographic analyses and reporting of clinical events were performed by experienced physicians at each study centre. In conclusion, compassionate use LuX-Valve Plus TTVR was associated with durable TR reduction over the course of 1-year follow-up with an observed improvement in heart failure and TR symptoms as well as RVRR. As previously reported for TTVR, the most common adverse events included need for permanent pacemaker implantation and bleeding complications. Open Access funding enabled and organized by Projekt DEAL. Conflict of interest: L.S. received speaker honoraria from Edwards Lifesciences. O.d.B. received institutional research grants and consulting fees from Abbott, Boston Scientific, Medtronic and SMT. J.E.M. received institutional research grant from Johnson and Jonson Heart Recovery, Novo Nordisk Foundation, speaker fee from Johnson and Jonson Heart Recovery and Abbott, advisory board from Boston Scientific and Magenta. K.C.Y.S. is physician proctor for Abbott Structural Heart, Boston Scientific, Edwards and Medtronic; and serves as consultant for Venus Medtech and Jenscare. A.C. is proctor for Abbott Vascular and received speaker fees for Abbott Vascular, Edwards Lifescience, GE Healthcare, BMS, MSD, Pfizer. J.D. received consulting fees from Abbott and Edwards Lifesciences. M.N. received proctoring and consulting fees from Abbott Vascular, Medtronic, Robocath. R.E.L. received speaker fees from Abbott, Edwards, Boston, Venus Medtech, Jenscare and Valgen. K.P.K. is a consultant to Edwards Lifesciences and ReCor Medical. J.H. received research support and speaker honoraria from Edwards Lifesciences. All other authors have nothing to disclose. Ralph Stephan von Bardeleben18, Sebastian Rosch18, André Vincentelli9, Gilles Lemesle9.

Authors

Institutions

Publication Details

Journal
European Journal of Heart Failure
Published
2025-08-18
DOI
https://doi.org/10.1002/ejhf.70010
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transcatheter Tricuspid Valve Replacement Using the LuX-Valve Plus system: 1-Year Compassionate Use Outcomes

O. Oliva, Julien Dreyfus, Chak-Yu So, Andrea Scotti et al.
European Journal of Heart Failure
Cardiac Valve Diseases and Treatments
article

Transcatheter Tricuspid Valve Replacement Using the LuX-Valve Plus system: 1-Year Compassionate Use Outcomes

O. Oliva, Julien Dreyfus, Chak-Yu So, Andrea Scotti, Pedro Villablanca, Thomas Modine, Ahmad Jabri, Jörg Hausleiter, Erwan Donal, Raj Makkar, Azeem Latib, Guillaume Leurent, Arnaud Sudre, Guillaume Bonnet, Neil Fam, Lukas Stolz, Augustin Coisne, Didier Tchétché, Jacob Eifer Mølller, Mohammed Nejjari, Yat‐Yin Lam, Ole De Backer, Philipp Lurz, Dhairya Patel, Geraldine Ong
article en

Abstract

Transcatheter tricuspid valve replacement (TTVR) has emerged as an important treatment tool for patients with severe tricuspid regurgitation (TR) and heart failure.1 Currently, one TTVR device is Food and Drug Administration and CE mark approved and several others are at different stages of development. For the transjugular LuX-Valve Plus TTVR system, evidence is consistently growing. Besides compassionate use 30-day outcome data,2 the TRAVEL study recently reported effective TR reduction (≤2+ in 95.5% of patients) in an Asian patient population, while being associated with low procedural complication rates (permanent pacemaker requirement in 1.6%, severe bleeding in 14.3%) and good 1-year survival (89.7%).3 Since 1-year real-world data outside of China are lacking, the present study aimed at investigating 1-year outcomes following compassionate use LuX-Valve Plus TTVR. The study included consecutive patients from 16 international centres who underwent LuX-Valve Plus TTVR from 2019 until 2024 in a compassionate use programme. Accordingly, no pre-specified in- or exclusion criteria were available and the individual screening process was left to the discretion of each individual centre. Procedural details of TTVR using the LuX-Valve Plus system have previously been described.4 One-year endpoints included clinical success according to the Tricuspid Valve Academic Research Consortium (TVARC),5 TR reduction, 1-year survival and survival free from heart failure hospitalization (HFH), changes in New York Heart Association (NYHA) functional class and symptoms of right ventricular (RV) failure, RV reverse remodelling (RVRR) as well TTVR-related adverse events. Numbers are presented as mean ± standard deviation or median with interquartile range (IQR). Two dependent samples were compared using the Wilcoxon test. A two-sided p-value of <0.05 yielded statistical significance. All analyses were performed using R (version 4.0.4) and SPSS (version 25, IBM, Armonk, NY, USA). The analysis was approved by each centre's local ethics committee and adheres to the principles outlined in the Declaration of Helsinki. The study included a total of 74 patients (mean age 75.9 ± 7.4 years; 56.8% women). TR was severe, massive and torrential in 13.7%, 21.9% and 64.4%, respectively. Patients were highly symptomatic (NYHA class ≥III 84.3%, peripheral oedema 81.1%, ascites 40.3%, pleural effusion 35.6%) and presented with advanced surgical risk (TRI-SCORE 5.9 ± 2.4 points). Renal function was impaired as represented by an estimated glomerular filtration rate of 52.4 ± 25.2 ml/min. The median N-terminal pro-B-type natriuretic peptide value was 1985 (IQR 1023–3668) pg/ml. The most common comorbidities within the study cohort were atrial fibrillation (90.4%), arterial hypertension (62.2%) and coronary artery disease (32.9%). TTVR reduced TR to ≤1+ and ≤2+ in 90.5% and 94.6% of patients, respectively. Residual TR was paravalvular in all cases. Intraprocedural success according to TVARC was achieved in 68 patients (91.1%) with a mean procedural time of 131 ± 40 min. The postprocedural tricuspid valve inflow gradient was 2.0 ± 1.2 mmHg. Overall, 42.5% of patients were discharged with prescription of direct oral anticoagulants and 53.5% with vitamin K antagonists. Antiplatelet therapy included acetylsalicylic acid in 5.7% of patients. One-year follow-up was available in 39 out of 41 eligible patients (alive and TTVR performed >1 year ago) (Figure 1). Clinical success at 1-year follow-up was 76.9% with durable TR reduction to ≤1+ in 78.4% and ≤2+ in 86.5% of patients (p < 0.001). Residual TR was of paravalvular nature in all cases. One-year survival and survival free from HFH were 77.7% and 66.8%, respectively. At 1-year follow-up, NYHA functional class improved to ≤ II in 94.6% of patients (vs. 15.7% at baseline, p < 0.001). Beyond that, TTVR was associated with an improvement in heart failure symptoms (peripheral oedema 22.2% vs. 81.1%, ascites 0% vs. 40.3%, pleural effusion 11.1% vs. 35.6%, all p < 0.001). While 6-min walking test distance remained statistically unchanged (baseline 274 ± 119 m; 1-year follow-up 295 ± 127 m, p = 0.345), the Kansas City Cardiomyopathy Questionnaire (KCCQ) significantly improved (baseline 54.4 ± 23.5; 1-year follow-up 68.7 ± 32.5, p = 0.017). Echocardiographically, TTVR was associated with numeric RVRR (reduction in RV midventricular diameter from 43.9 ± 8.9 mm at baseline to 36.3 ± 9.7 mm at 1-year follow-up, p = 0.087) and a decrease in RV function (decrease in tricuspid annular plane systolic excursion from 17.2 ± 4.6 mm at baseline to 15.4 ± 5.5 mm at 1-year follow-up, p = 0.024; RV fractional area change from 37.3 ± 9.0% to 35.6 ± 8.0%, p = 0.249). Within the whole study period no events of myocardial infarction, stroke, pulmonary embolism, or valve thrombosis were noted. While five patients (6.7%) suffered bleeding complications within the index hospitalization, no further bleeding events were noted during follow-up. No association between bleeding complications and antiplatelet or anticoagulation therapy was observed. Among 50 pacemaker naïve individuals, three patients (6.0%) required permanent pacemaker implantation within the first 30 days after the procedure with one further patient 8 months after TTVR due to atrial fibrillation with slow ventricular response (cumulative incidence at 1 year 8.0%). In summary, this is the largest available compassionate use LuX-Valve Plus TTVR experience available today. Compared to controlled data from the recently published TRAVEL trial, 1-year survival and survival free from HFH were lower among real-world patients (78% vs. 90% and 67% vs. 85% for this study vs. TRAVEL, respectively) probably reflecting a more selected patient cohort within the trial environment.3 Beyond that, many patients within this compassionate use cohort were ineligible for alternative treatment options due to comorbidities or challenging anatomical conditions. Comparable results were observed for TR reduction to ≤2+ (87% vs. 95%). With a cumulative pacemaker implantation rate of 8.0% of pacemaker naïve patients at 1 year, numbers were higher under real-world conditions compared to trial data (1.6%). Noteworthy, those numbers are lower compared to other TTVR devices with more radial anchoring force (e.g. ~25% of pacemaker naïve patients in TRISCEND II).6 Alike reported in the TRAVEL study, TTVR using the LuX-Valve Plus system was associated with an improvement in quality of life as assessed by the KCCQ. In line with previous reports, RV function numerically declined after TTVR reflecting a pseudonormalization of RV function from a previously hyperactive state.7-9 This study is subject to a number of limitations, primarily due to the retrospective nature of the registry (no control group, no echocardiographic core laboratory or clinical event adjudication committee). However, echocardiographic analyses and reporting of clinical events were performed by experienced physicians at each study centre. In conclusion, compassionate use LuX-Valve Plus TTVR was associated with durable TR reduction over the course of 1-year follow-up with an observed improvement in heart failure and TR symptoms as well as RVRR. As previously reported for TTVR, the most common adverse events included need for permanent pacemaker implantation and bleeding complications. Open Access funding enabled and organized by Projekt DEAL. Conflict of interest: L.S. received speaker honoraria from Edwards Lifesciences. O.d.B. received institutional research grants and consulting fees from Abbott, Boston Scientific, Medtronic and SMT. J.E.M. received institutional research grant from Johnson and Jonson Heart Recovery, Novo Nordisk Foundation, speaker fee from Johnson and Jonson Heart Recovery and Abbott, advisory board from Boston Scientific and Magenta. K.C.Y.S. is physician proctor for Abbott Structural Heart, Boston Scientific, Edwards and Medtronic; and serves as consultant for Venus Medtech and Jenscare. A.C. is proctor for Abbott Vascular and received speaker fees for Abbott Vascular, Edwards Lifescience, GE Healthcare, BMS, MSD, Pfizer. J.D. received consulting fees from Abbott and Edwards Lifesciences. M.N. received proctoring and consulting fees from Abbott Vascular, Medtronic, Robocath. R.E.L. received speaker fees from Abbott, Edwards, Boston, Venus Medtech, Jenscare and Valgen. K.P.K. is a consultant to Edwards Lifesciences and ReCor Medical. J.H. received research support and speaker honoraria from Edwards Lifesciences. All other authors have nothing to disclose. Ralph Stephan von Bardeleben18, Sebastian Rosch18, André Vincentelli9, Gilles Lemesle9.

European Journal of Heart FailureVol. 27(11)
Cedars-Sinai Medical Center (US), St. Michael's Hospital (CA), Albert Einstein College of Medicine (US), Valve (United States) (US), Montefiore Medical Center (US), Henry Ford Health System (US), Inserm (FR), Chinese University of Hong Kong (HK), University of Toronto (CA), Johannes Gutenberg University Mainz (DE), Institut Pasteur de Lille (FR), University Hospital Complex Of Vigo (ES), Rigshospitalet (DK), Centre Hospitalier Universitaire de Lille (FR), LMU Klinikum (DE), Galicia Sur Biomedical Foundation (ES), University Medical Center of the Johannes Gutenberg University Mainz (DE), Complejo Hospitalario de Salamanca (ES), Prince of Wales Hospital (CN), German Centre for Cardiovascular Research (DE), Instituto de Investigación Biomédica de Salamanca (ES), Clinique Pasteur (FR), Cedars-Sinai Smidt Heart Institute (US), Centre Cardiologique du Nord (FR), Centre Hospitalier Universitaire de Rennes (FR), Ludwig-Maximilians-Universität München (DE)
Zero hunger
Openalex Percentile: Top 66%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.