Wellhead Flange Failure Analysis and Composite Load-Bearing Capacity Under Ultrahigh Pressure

Summary As the wellhead pressure escalates, wellhead equipment is confronted with a series of significant challenges that impose increasingly stringent demands on the performance and reliability of wellhead flanges. Given the current absence of design guidelines for ultrahigh pressure (UHP) wellhead equipment rated at 175 MPa, we introduces a methodology for determining design parameters for nonstandard UHP wellhead flanges, leveraging the existing API SPEC 6A standards. The reliability of the calculation results of the finite element model (FEM) based on the elastic-plastic constitutive model was verified through the analytical model and experimental testing. The structural integrity analysis of the nonstandard flange was carried out using the finite element analysis (FEA) method. The results show that the stress check of the flange meets the API criteria, and the contact pressure is at least 4.5 times the design pressure, which provides a design reference for the development of UHP nonstandard flanges. Further, the effects of the deterioration of lubrication conditions and bolt pretightening on the sealing performance that may occur in actual engineering are explored. In addition, the load-capacity line set of the nonstandard flange is computed using the composite load-bearing-capacity line-set-determination approach derived from the API TR 6AF2 leakage criteria. The calculation results of the extreme working conditions on the line set show that the sealing contact still has more than three times the contact pressure. This study enhances and further refines the sealing design methodology for 175-MPa UHP wellhead flanges and provides a reference for determining the allowable loads under composite loading conditions for wellhead flanges in UHP.

Authors

Institutions

Publication Details

Journal
SPE Journal
Published
2025-08-18
DOI
https://doi.org/10.2118/230285-pa
Primary Topic
Engineering Structural Analysis Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wellhead Flange Failure Analysis and Composite Load-Bearing Capacity Under Ultrahigh Pressure

Fuqiang Dong, Qiping Dai, Chuanjun Han, Yi Zhao
SPE Journal
Engineering Structural Analysis Methods
article

Wellhead Flange Failure Analysis and Composite Load-Bearing Capacity Under Ultrahigh Pressure

Fuqiang Dong, Qiping Dai, Chuanjun Han, Yi Zhao
article en

Abstract

Summary As the wellhead pressure escalates, wellhead equipment is confronted with a series of significant challenges that impose increasingly stringent demands on the performance and reliability of wellhead flanges. Given the current absence of design guidelines for ultrahigh pressure (UHP) wellhead equipment rated at 175 MPa, we introduces a methodology for determining design parameters for nonstandard UHP wellhead flanges, leveraging the existing API SPEC 6A standards. The reliability of the calculation results of the finite element model (FEM) based on the elastic-plastic constitutive model was verified through the analytical model and experimental testing. The structural integrity analysis of the nonstandard flange was carried out using the finite element analysis (FEA) method. The results show that the stress check of the flange meets the API criteria, and the contact pressure is at least 4.5 times the design pressure, which provides a design reference for the development of UHP nonstandard flanges. Further, the effects of the deterioration of lubrication conditions and bolt pretightening on the sealing performance that may occur in actual engineering are explored. In addition, the load-capacity line set of the nonstandard flange is computed using the composite load-bearing-capacity line-set-determination approach derived from the API TR 6AF2 leakage criteria. The calculation results of the extreme working conditions on the line set show that the sealing contact still has more than three times the contact pressure. This study enhances and further refines the sealing design methodology for 175-MPa UHP wellhead flanges and provides a reference for determining the allowable loads under composite loading conditions for wellhead flanges in UHP.

SPE JournalVol. 30(10)
Southwest Petroleum University (CN), Oil and Gas Center (CN)
Openalex Percentile: Top 79%
Engineering Structural Analysis Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Wellhead Flange Failure Analysis and Composite Load-Bearing Capacity Under Ultrahigh Pressure — Fuqiang Dong, Qiping Dai, et al. · SPE Journal (2025) | TGRS Research Map | TGRS