Dynamic Calibration of Quartz Flexure Accelerometers

The dynamic behavior of quartz flexure accelerometers remains a subject of ongoing investigation, particularly in areas such as theoretical modeling, standardization, calibration methodology, and performance evaluation. To address the limitation of conventional static calibration models in accurately representing accelerometer responses under dynamic acceleration excitation, a dynamic calibration model is proposed. A mathematical model is first developed based on the physical mechanism of the accelerometer, characterizing its intrinsic dynamic response. Simulation-based analysis demonstrates that the proposed dynamic model offers significantly improved accuracy compared to traditional static approaches. Furthermore, a dynamic calibration method leveraging a dual-axis precision centrifuge is designed and validated. The results confirm that the proposed approach enables the precise calibration of quartz flexure accelerometers in accordance with the dynamic model. The calibration of the dynamic parameter yields a relative standard deviation of -0.048%.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-08-16
DOI
https://doi.org/10.3390/s25165096
Citations
1
Primary Topic
Advanced MEMS and NEMS Technologies
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Calibration of Quartz Flexure Accelerometers

Xiaoming Sheng, Xizhe Wang, Kai Zhang, Shu Yang et al.
1 citations
Sensors
Advanced MEMS and NEMS Technologies
0.73
article

Dynamic Calibration of Quartz Flexure Accelerometers

Xiaoming Sheng, Xizhe Wang, Kai Zhang, Shu Yang, Wenying Chen
article en
1 citations

Abstract

The dynamic behavior of quartz flexure accelerometers remains a subject of ongoing investigation, particularly in areas such as theoretical modeling, standardization, calibration methodology, and performance evaluation. To address the limitation of conventional static calibration models in accurately representing accelerometer responses under dynamic acceleration excitation, a dynamic calibration model is proposed. A mathematical model is first developed based on the physical mechanism of the accelerometer, characterizing its intrinsic dynamic response. Simulation-based analysis demonstrates that the proposed dynamic model offers significantly improved accuracy compared to traditional static approaches. Furthermore, a dynamic calibration method leveraging a dual-axis precision centrifuge is designed and validated. The results confirm that the proposed approach enables the precise calibration of quartz flexure accelerometers in accordance with the dynamic model. The calibration of the dynamic parameter yields a relative standard deviation of -0.048%.

SensorsVol. 25(16)
China Academy of Engineering Physics (CN)
National Natural Science Foundation of China, China Academy of Engineering Physics, National Safety Academic Fund
Openalex Percentile: Top 25%
Advanced MEMS and NEMS Technologies
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.