Numerically Enhanced Interfacings for Average-Value Models of Voltage-Source Converters in Nodal-Based EMT Simulators

Efficient simulations of converter-dominated power systems and microgrids significantly rely on average-value models (AVMs) of the converters. The conventional AVMs of voltage-source converters (VSCs) typically require a time-step delay for interfacing with the external circuits in non-iterative nodal-based electromagnetic transient (EMT) programs. This time-step relaxation may lead to numerical inaccuracy and/or instability for simulations with large time-step sizes. This paper presents several alternative formulations and interfacing techniques for AVMs of VSCs, which eliminate undesirable time-step delays and result in robust and reliable interfaces that allow simulations at large time steps without significant compromise in numerical accuracy. This is achieved by formulating the VSCs as conductance matrices (and history terms), which are computed simultaneously with the solution of the external network. The advantages of the proposed techniques over the conventional methods are demonstrated in simulations of a VSC-dominated power system using the EMT program PSCAD.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-08-18
DOI
https://doi.org/10.3390/en18164400
Primary Topic
Real-time simulation and control systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerically Enhanced Interfacings for Average-Value Models of Voltage-Source Converters in Nodal-Based EMT Simulators

Juri Jatskevich, Seyyedmilad Ebrahimi
Energies
Real-time simulation and control systems
article

Numerically Enhanced Interfacings for Average-Value Models of Voltage-Source Converters in Nodal-Based EMT Simulators

Juri Jatskevich, Seyyedmilad Ebrahimi
article en

Abstract

Efficient simulations of converter-dominated power systems and microgrids significantly rely on average-value models (AVMs) of the converters. The conventional AVMs of voltage-source converters (VSCs) typically require a time-step delay for interfacing with the external circuits in non-iterative nodal-based electromagnetic transient (EMT) programs. This time-step relaxation may lead to numerical inaccuracy and/or instability for simulations with large time-step sizes. This paper presents several alternative formulations and interfacing techniques for AVMs of VSCs, which eliminate undesirable time-step delays and result in robust and reliable interfaces that allow simulations at large time steps without significant compromise in numerical accuracy. This is achieved by formulating the VSCs as conductance matrices (and history terms), which are computed simultaneously with the solution of the external network. The advantages of the proposed techniques over the conventional methods are demonstrated in simulations of a VSC-dominated power system using the EMT program PSCAD.

EnergiesVol. 18(16)
University of British Columbia (CA), Washington State University (US)
Openalex Percentile: Top 75%
Real-time simulation and control systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.