An Electromagnetic Transient Simulation Model of MMC-BESS for Various Operating Conditions

Existing electromagnetic transient (EMT) simulation models of the modular multilevel converter with an embedded battery energy storage system (MMC-BESS) often suffer from computational inefficiencies and difficulties in accurately simulating fault behaviors. To address these issues, this paper proposes an efficient EMT model for the MMC-BESS. The proposed model improves the detailed equivalent model (DEM) by accounting for the complex scenarios where both switches in the same leg are simultaneously turned off. The converter blocked state is simulated by incorporating auxiliary PSCAD switches and leveraging its built-in interpolation algorithms, while the battery disconnection is simulated by using supplementary decision formulas. Furthermore, a speedup calculation method is introduced to further optimize simulation efficiency. Evaluation of the proposed model is performed in the context of an HVDC system in PSCAD/EMTDC simulation environment, encompassing steady-state operation, transient responses, and faulted operating conditions. The results confirm the simulation accuracy and efficiency of the proposed model.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Delivery
Published
2025-08-18
DOI
https://doi.org/10.1109/tpwrd.2025.3599870
Primary Topic
Induction Heating and Inverter Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Electromagnetic Transient Simulation Model of MMC-BESS for Various Operating Conditions

Minghao Huang, Shunliang Wang, Hao Tu, Junpeng Ma et al.
IEEE Transactions on Power Delivery
Induction Heating and Inverter Technology
article

An Electromagnetic Transient Simulation Model of MMC-BESS for Various Operating Conditions

Minghao Huang, Shunliang Wang, Hao Tu, Junpeng Ma, Guangqiang Peng, Rui Zhang, Tianqi Liu
article en

Abstract

Existing electromagnetic transient (EMT) simulation models of the modular multilevel converter with an embedded battery energy storage system (MMC-BESS) often suffer from computational inefficiencies and difficulties in accurately simulating fault behaviors. To address these issues, this paper proposes an efficient EMT model for the MMC-BESS. The proposed model improves the detailed equivalent model (DEM) by accounting for the complex scenarios where both switches in the same leg are simultaneously turned off. The converter blocked state is simulated by incorporating auxiliary PSCAD switches and leveraging its built-in interpolation algorithms, while the battery disconnection is simulated by using supplementary decision formulas. Furthermore, a speedup calculation method is introduced to further optimize simulation efficiency. Evaluation of the proposed model is performed in the context of an HVDC system in PSCAD/EMTDC simulation environment, encompassing steady-state operation, transient responses, and faulted operating conditions. The results confirm the simulation accuracy and efficiency of the proposed model.

IEEE Transactions on Power DeliveryVol. 40(5)
Sichuan University (CN), China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 79%
Induction Heating and Inverter Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.