Estimating vastus lateralis muscle volume from a single ultrasound image

The assessment of skeletal muscle volume is valuable for fundamental research and clinical practice, but remains limited in larger cohorts due to its time-consuming nature. Here, we developed a method to accurately estimate vastus lateralis (VL) muscle volume based on a single measurement of anatomical cross-sectional area (ACSA) or tissue thickness. Sixty-nine healthy participants (20-91 years) volunteered. In a subgroup (n = 34) we measured VL volume and ACSAs at 10% intervals along the muscle length to derive a VL muscle shape factor. We subsequently estimated VL volume by multiplying this muscle shape factor with muscle length and a single measure of ACSA at 50% muscle length (ACSA<sub>VL50%</sub>) or an estimated ACSA<sub>VL50%</sub> from a single ultrasound scan of tissue thickness in an independent cohort (n = 35). VL muscle shape factor was determined by integrating a fourth-order polynomial of muscle length and ACSA, and was dependent on muscle size. Estimating muscle volume had a high accuracy (R²=0.976, CCC = 0.987), low bias and error (< 8.5%) in both the main cohort and an independent validation group. Estimating muscle volume from stitching 2D images at 50% muscle length or estimating ACSA with a geometric model explained 91-95% of variance in measured volumes, with high accuracy and concordance correlation coefficients. VL muscle volume can be estimated by multiplying a muscle shape factor with muscle length and ACSA<sub>VL50%</sub> from a single ultrasound image. We present a novel, cost-effective, rapid, yet accurate assessment of VL muscle mass for (large-scale) studies and clinical practice.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-08-18
DOI
https://doi.org/10.1038/s41598-025-11437-5
Primary Topic
Body Composition Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimating vastus lateralis muscle volume from a single ultrasound image

Rob C. I. Wüst, Richard T. Jaspers, Peter J.M. Weijs, Michael Tieland et al.
Scientific Reports
Body Composition Measurement Techniques
article

Estimating vastus lateralis muscle volume from a single ultrasound image

Rob C. I. Wüst, Richard T. Jaspers, Peter J.M. Weijs, Michael Tieland, Moritz Eggelbusch, Guido Weide, Stephan van der Zwaard, Jantine van den Helder, Luuk Vos, Renske N. Vergeer
article en

Abstract

The assessment of skeletal muscle volume is valuable for fundamental research and clinical practice, but remains limited in larger cohorts due to its time-consuming nature. Here, we developed a method to accurately estimate vastus lateralis (VL) muscle volume based on a single measurement of anatomical cross-sectional area (ACSA) or tissue thickness. Sixty-nine healthy participants (20-91 years) volunteered. In a subgroup (n = 34) we measured VL volume and ACSAs at 10% intervals along the muscle length to derive a VL muscle shape factor. We subsequently estimated VL volume by multiplying this muscle shape factor with muscle length and a single measure of ACSA at 50% muscle length (ACSA<sub>VL50%</sub>) or an estimated ACSA<sub>VL50%</sub> from a single ultrasound scan of tissue thickness in an independent cohort (n = 35). VL muscle shape factor was determined by integrating a fourth-order polynomial of muscle length and ACSA, and was dependent on muscle size. Estimating muscle volume had a high accuracy (R²=0.976, CCC = 0.987), low bias and error (< 8.5%) in both the main cohort and an independent validation group. Estimating muscle volume from stitching 2D images at 50% muscle length or estimating ACSA with a geometric model explained 91-95% of variance in measured volumes, with high accuracy and concordance correlation coefficients. VL muscle volume can be estimated by multiplying a muscle shape factor with muscle length and ACSA<sub>VL50%</sub> from a single ultrasound image. We present a novel, cost-effective, rapid, yet accurate assessment of VL muscle mass for (large-scale) studies and clinical practice.

Scientific ReportsVol. 15(1)
Deakin University (AU), Amsterdam University Medical Centers (NL), Amsterdam University of Applied Sciences (NL), Vrije Universiteit Amsterdam (NL), University of Amsterdam (NL)
Technische Universität München
Openalex Percentile: Top 73%
Body Composition Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.