Condition Monitoring and Fault Detection Analysis of Induced-Draft Fan Using Remaining Useful Life Estimation from Vibration Signals

In this paper, the degradation model is assumed and the model parameters are estimated from the vibration signal data of the induced-drift blower, and the result is used to diagnose equipment abnormalities and predict remaining useful life(RUL). Using the field degradation data, the model parameters in the degradation model were estimated using the maximum likelihood estimation method. In the case of the linear degradation model, the slope parameter was tested to find the starting time period of the degradation process and the remaining useful life is estimated repeatedly using the accelerated degradation model. Using the field vibration data the suitable degradation models and the effective monitoring and estimation methods for preventive maintenance are analyzed. Time period 1 to 4 were sections in which degradation of equipment did not occur. For time period 5 to 6, the linear increase in the vibration signal was verified through the linear degradation model. After time period 7, the degradation has been accelerated exponentially. The remaining useful life was estimated through the accelerated degradation model. These results shows that the alert signal in time period 5 to 6, the alarm signal in period 7 to 9, and the warning signal after time period 10 should be displayed based on the diagnostic analysis. The vibration signal data obtained from the Induce-drift blower was used in the degradation model, and the model parameters of degradation model were estimated using the field before the failure obtained from the field to check whether the equipment was deteriorated and whether the residual useful life is enough to delay preventive maintenance to the next time period.

Authors

Publication Details

Journal
Journal of Korean Institute of Industrial Engineers
Published
2025-06-15
DOI
https://doi.org/10.7232/jkiie.2025.51.3.217
Primary Topic
Machine Fault Diagnosis Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Condition Monitoring and Fault Detection Analysis of Induced-Draft Fan Using Remaining Useful Life Estimation from Vibration Signals

Won-Young Yun, Myung-Kyo Seo
Journal of Korean Institute of Industrial Engineers
Machine Fault Diagnosis Techniques
article

Condition Monitoring and Fault Detection Analysis of Induced-Draft Fan Using Remaining Useful Life Estimation from Vibration Signals

Won-Young Yun, Myung-Kyo Seo
article en

Abstract

In this paper, the degradation model is assumed and the model parameters are estimated from the vibration signal data of the induced-drift blower, and the result is used to diagnose equipment abnormalities and predict remaining useful life(RUL). Using the field degradation data, the model parameters in the degradation model were estimated using the maximum likelihood estimation method. In the case of the linear degradation model, the slope parameter was tested to find the starting time period of the degradation process and the remaining useful life is estimated repeatedly using the accelerated degradation model. Using the field vibration data the suitable degradation models and the effective monitoring and estimation methods for preventive maintenance are analyzed. Time period 1 to 4 were sections in which degradation of equipment did not occur. For time period 5 to 6, the linear increase in the vibration signal was verified through the linear degradation model. After time period 7, the degradation has been accelerated exponentially. The remaining useful life was estimated through the accelerated degradation model. These results shows that the alert signal in time period 5 to 6, the alarm signal in period 7 to 9, and the warning signal after time period 10 should be displayed based on the diagnostic analysis. The vibration signal data obtained from the Induce-drift blower was used in the degradation model, and the model parameters of degradation model were estimated using the field before the failure obtained from the field to check whether the equipment was deteriorated and whether the residual useful life is enough to delay preventive maintenance to the next time period.

Journal of Korean Institute of Industrial EngineersVol. 51(3)
Climate action
Openalex Percentile: Top 75%
Machine Fault Diagnosis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.