Myocardial ischemic classification using a knowledge-guided polar transformer in two-dimensional echocardiography

Myocardial ischemia, characterized by inadequate blood supply to the heart muscles, is critical to cardiovascular diseases. Timely and accurate identification of ischemic segments is essential for prompt intervention and patient care. This study developed a Transformer-based model to identify myocardial ischemia in left ventricle short-axis (LVSA) two-dimensional echocardiography (2DE) images where a novel Knowledge-Guided Polar Transformer (KGPT) was proposed that integrated the unique characteristics of 2DE images with the prior clinical knowledge. 305 patients (aged 57.6 ± 8.8 years) were selected and underwent transthoracic echocardiography within 1–3 days prior to invasive coronary angiography (ICA). With ICA and quantitative flow ratio as the gold standard of myocardial ischemia, the KGPT model was trained to classify the LVSA 2DE images as ischemia or non-ischemia by capturing spatial features in a radial orientation. Its performance was evaluated with five-fold cross-validation and receiver operating characteristic curve (ROC) analysis. It achieved an area under ROC (AUC) of 0.8326 ± 0.0906, with an accuracy of 79.50 ± 5.40 %, precision of 79.07 ± 6.70 %, recall of 80.79 ± 7.87 %, and F1 score of 78.43 ± 6.56 %. In comparison, the original Swin-Transformer model produced an AUC of 0.7011 ± 0.0334, accuracy of 70.20 ± 1.04 %, precision of 68.58 ± 3.12 %, recall of 63.21 ± 3.60 %, and F1 score of 63.13 ± 3.78 %. The differences were statistically significant (P < 0.05). The KGPT also demonstrated significantly superior performance to radiologists. It effectively classifies ischemic regions in 2DE images, presenting a promising tool for diagnosing myocardial ischemia. The integration of clinical knowledge with Transformer enhances the accuracy and reliability of ischemia classification, potentially revolutionizing the diagnosis and monitoring of myocardial ischemic diseases.

Authors

Institutions

Publication Details

Journal
Engineering Applications of Artificial Intelligence
Published
2025-07-25
DOI
https://doi.org/10.1016/j.engappai.2025.111871
Citations
1
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Myocardial ischemic classification using a knowledge-guided polar transformer in two-dimensional echocardiography

Zhiping P. Pang, Yanhui Guo, Yaping Du, Siqi Guo et al.
1 citations
Engineering Applications of Artificial Intelligence
Advanced MRI Techniques and Applications
1.36
article

Myocardial ischemic classification using a knowledge-guided polar transformer in two-dimensional echocardiography

Zhiping P. Pang, Yanhui Guo, Yaping Du, Siqi Guo, Shuang Chen, Bo Yu, Guo-Qing Du
article en
1 citations

Abstract

Myocardial ischemia, characterized by inadequate blood supply to the heart muscles, is critical to cardiovascular diseases. Timely and accurate identification of ischemic segments is essential for prompt intervention and patient care. This study developed a Transformer-based model to identify myocardial ischemia in left ventricle short-axis (LVSA) two-dimensional echocardiography (2DE) images where a novel Knowledge-Guided Polar Transformer (KGPT) was proposed that integrated the unique characteristics of 2DE images with the prior clinical knowledge. 305 patients (aged 57.6 ± 8.8 years) were selected and underwent transthoracic echocardiography within 1–3 days prior to invasive coronary angiography (ICA). With ICA and quantitative flow ratio as the gold standard of myocardial ischemia, the KGPT model was trained to classify the LVSA 2DE images as ischemia or non-ischemia by capturing spatial features in a radial orientation. Its performance was evaluated with five-fold cross-validation and receiver operating characteristic curve (ROC) analysis. It achieved an area under ROC (AUC) of 0.8326 ± 0.0906, with an accuracy of 79.50 ± 5.40 %, precision of 79.07 ± 6.70 %, recall of 80.79 ± 7.87 %, and F1 score of 78.43 ± 6.56 %. In comparison, the original Swin-Transformer model produced an AUC of 0.7011 ± 0.0334, accuracy of 70.20 ± 1.04 %, precision of 68.58 ± 3.12 %, recall of 63.21 ± 3.60 %, and F1 score of 63.13 ± 3.78 %. The differences were statistically significant (P < 0.05). The KGPT also demonstrated significantly superior performance to radiologists. It effectively classifies ischemic regions in 2DE images, presenting a promising tool for diagnosing myocardial ischemia. The integration of clinical knowledge with Transformer enhances the accuracy and reliability of ischemia classification, potentially revolutionizing the diagnosis and monitoring of myocardial ischemic diseases.

Engineering Applications of Artificial IntelligenceVol. 160
Harbin Medical University (CN), Sun Yat-sen University (CN), Sun Yat-sen Memorial Hospital (CN), Second Affiliated Hospital of Harbin Medical University (CN), University of Illinois at Springfield (US)
Good health and well-being
Openalex Percentile: Top 17%
Advanced MRI Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.