The Effect of Railway Environment on the Insulation Performance of Catenary Insulators

The form of the railway track includes open route, bridge, tunnel, and even tracks close to the coast. Therefore, insulators for catenary are exposed to more dust, salt, and moisture than general electrical equipment installed on roads. Considering this environment, insulators for AC 25kV catenary lines are designed and applied with an insulation class of 46kV and an specifie creepage distance(SCD) of Very Heavy pollution level exceeding 25mm/kV. However, there have been 185 cases of catenary insulator flashover in the past 13 years. In this paper, we analyzed cases of flashover caused by dust and moisture in tunnels, flashover caused by salt damage, and flashover of polymer insulators in high-speed railway open route, and examined the effect of railway environment on the insulation performance of catenary insulators.

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2025-08-07
DOI
https://doi.org/10.5370/kiee.2025.74.8.1418
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Railway Environment on the Insulation Performance of Catenary Insulators

Jang-Young Choi, Hae‐Won Lee
The Transactions of The Korean Institute of Electrical Engineers
Engineering Applied Research
article

The Effect of Railway Environment on the Insulation Performance of Catenary Insulators

Jang-Young Choi, Hae‐Won Lee
article en

Abstract

The form of the railway track includes open route, bridge, tunnel, and even tracks close to the coast. Therefore, insulators for catenary are exposed to more dust, salt, and moisture than general electrical equipment installed on roads. Considering this environment, insulators for AC 25kV catenary lines are designed and applied with an insulation class of 46kV and an specifie creepage distance(SCD) of Very Heavy pollution level exceeding 25mm/kV. However, there have been 185 cases of catenary insulator flashover in the past 13 years. In this paper, we analyzed cases of flashover caused by dust and moisture in tunnels, flashover caused by salt damage, and flashover of polymer insulators in high-speed railway open route, and examined the effect of railway environment on the insulation performance of catenary insulators.

The Transactions of The Korean Institute of Electrical EngineersVol. 74(8)
Openalex Percentile: Top 78%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.