Effect of water temperature on flow regimes and reynolds number in a passive natural circulation cooling system

Natural circulation flow is an important phenomenon of passive cooling systems in nuclear reactor thermal management during accidents. This experimental study investigates the effect of varying water temperatures on flow regimes and Reynolds number within a passive natural circulation system. The research was conducted using a rectangular TP-loop (FASSIP-04 Ver.2) made of 1-inch SS304 pipe, 6 m high and 1.32 m wide. The water temperature setting was varied at 45°C, 55°C, 65°C, and 75°C, with a heating power of 4.2 kW, and the cooling tank was maintained at 10°C. Observations were made during transient heating, steady-state (for 3 hours), and transient cooling phases. Results show that increasing the heating tank temperature reduces fluid density and viscosity, thereby enhancing buoyancy-driven flow. This led to a transition in flow regimes from laminar to turbulent as the temperature increased. The Reynolds number increased by 169.38% when the water temperature was raised from 45°C to 75°C. Unstable flow behaviour, including fluctuating amplitudes and frequencies, was observed—characteristic of natural circulation dynamics. The study confirms a strong correlation between thermal variation and flow regime transition, providing insights into the performance of passive cooling systems under varying thermal loads.

Authors

Institutions

Publication Details

Journal
Jurnal POLIMESIN
Published
2025-06-30
DOI
https://doi.org/10.30811/jpl.v23i3.6665
Primary Topic
Nuclear Engineering Thermal-Hydraulics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of water temperature on flow regimes and reynolds number in a passive natural circulation cooling system

Putut Hery Setiawan, Almira Citra Amelia, Agus Sunjarianto Pamitran, Mulya Juarsa et al.
Jurnal POLIMESIN
Nuclear Engineering Thermal-Hydraulics
article

Effect of water temperature on flow regimes and reynolds number in a passive natural circulation cooling system

Putut Hery Setiawan, Almira Citra Amelia, Agus Sunjarianto Pamitran, Mulya Juarsa, Ridho Irwansyah, Arif Adtyas Budiman, Adhika Enggar Pamungkas, Dwi Yuliaji, Shendy Akbar Maryadi
article en

Abstract

Natural circulation flow is an important phenomenon of passive cooling systems in nuclear reactor thermal management during accidents. This experimental study investigates the effect of varying water temperatures on flow regimes and Reynolds number within a passive natural circulation system. The research was conducted using a rectangular TP-loop (FASSIP-04 Ver.2) made of 1-inch SS304 pipe, 6 m high and 1.32 m wide. The water temperature setting was varied at 45°C, 55°C, 65°C, and 75°C, with a heating power of 4.2 kW, and the cooling tank was maintained at 10°C. Observations were made during transient heating, steady-state (for 3 hours), and transient cooling phases. Results show that increasing the heating tank temperature reduces fluid density and viscosity, thereby enhancing buoyancy-driven flow. This led to a transition in flow regimes from laminar to turbulent as the temperature increased. The Reynolds number increased by 169.38% when the water temperature was raised from 45°C to 75°C. Unstable flow behaviour, including fluctuating amplitudes and frequencies, was observed—characteristic of natural circulation dynamics. The study confirms a strong correlation between thermal variation and flow regime transition, providing insights into the performance of passive cooling systems under varying thermal loads.

Jurnal POLIMESINVol. 23(3)
Universitas Gadjah Mada (ID), University of Indonesia (ID), ADA University (AZ), National Research and Innovation Agency (ID)
Badan Riset dan Inovasi Nasional, Lembaga Pengelola Dana Pendidikan
Clean water and sanitation
Openalex Percentile: Top 71%
Nuclear Engineering Thermal-Hydraulics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.