A passive Lab-on-PCB microsystem for non-enzymatic quantification of glucose

This paper presents and successfully demonstrates a new form of passive Lab-on-printed circuit board (PCB) diagnostic platform for the quantification of glucose, as required for pumpless applications such as wearable diagnostic patches. The platform exploits copper oxide (CuO) nanoparticles for non-enzymatic, electrochemical glucose quantification, to achieve the high sensitivity and linear range of operation that is necessary for sweat or interstitial fluid sample analysis. As a result, the platform exhibits a low limit of detection (LoD) of 2.1 μM and a high sensitivity of 456 μA mM −1 ·cm −2 , coupled with an excellent specificity against common glucose interfering species. The seamless integration of passive microfluidics and an electrochemical glucose biosensor is firstly outlined, and is fabricated using standard photolithography techniques in an up-scalable glucose quantification platform. The detection of glucose under two sample flow conditions is investigated in detail, including both static and dynamic conditions, revealing that when subject to a continuous flow the microsystem demonstrates an increase in sensitivity and a reduced linear range. This work demonstrates that our new passive Lab-on-printed circuit board (PCB) diagnostic platform can be successfully implemented under continuous sample flow conditions, and is therefore ideally suited to wearable diagnostic patch applications. In addition, the measured performance exceeds static flow approaches that have reported to date, including paper-based approaches. • New passive flexible Lab-on-PCB microsystem successfully demonstrated for wearable applications. • Non-enzymatic electrochemical biosensor integrated with clinically relevant performance characteristics. • Performance under sample flow shown to significantly affect microsystem performance characteristics.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics X
Published
2025-08-08
DOI
https://doi.org/10.1016/j.biosx.2025.100670
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A passive Lab-on-PCB microsystem for non-enzymatic quantification of glucose

Anna Regoutz, Yujiang Zhu, Despina Moschou, Pavlos Menelaou
Biosensors and Bioelectronics X
Electrochemical sensors and biosensors
article

A passive Lab-on-PCB microsystem for non-enzymatic quantification of glucose

Anna Regoutz, Yujiang Zhu, Despina Moschou, Pavlos Menelaou
article en

Abstract

This paper presents and successfully demonstrates a new form of passive Lab-on-printed circuit board (PCB) diagnostic platform for the quantification of glucose, as required for pumpless applications such as wearable diagnostic patches. The platform exploits copper oxide (CuO) nanoparticles for non-enzymatic, electrochemical glucose quantification, to achieve the high sensitivity and linear range of operation that is necessary for sweat or interstitial fluid sample analysis. As a result, the platform exhibits a low limit of detection (LoD) of 2.1 μM and a high sensitivity of 456 μA mM −1 ·cm −2 , coupled with an excellent specificity against common glucose interfering species. The seamless integration of passive microfluidics and an electrochemical glucose biosensor is firstly outlined, and is fabricated using standard photolithography techniques in an up-scalable glucose quantification platform. The detection of glucose under two sample flow conditions is investigated in detail, including both static and dynamic conditions, revealing that when subject to a continuous flow the microsystem demonstrates an increase in sensitivity and a reduced linear range. This work demonstrates that our new passive Lab-on-printed circuit board (PCB) diagnostic platform can be successfully implemented under continuous sample flow conditions, and is therefore ideally suited to wearable diagnostic patch applications. In addition, the measured performance exceeds static flow approaches that have reported to date, including paper-based approaches. • New passive flexible Lab-on-PCB microsystem successfully demonstrated for wearable applications. • Non-enzymatic electrochemical biosensor integrated with clinically relevant performance characteristics. • Performance under sample flow shown to significantly affect microsystem performance characteristics.

Biosensors and Bioelectronics XVol. 26
University of Oxford (GB), University College London (GB), University of Bath (GB)
Zero hunger
Openalex Percentile: Top 81%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.