Risk Assessment of First Commutation Failure Caused by Single-phase Harmonic Voltage

Commutation failure is a research hotspot in the field of line commutated converter-based high voltage direct current transmission (LCC-HVDC). Current studies primarily focus on commutation failures caused by AC system faults, while research on harmonic voltage-induced commutation failures requires further exploration. First, starting from the mechanism of commutation failure and combining the analysis of a commutation process involving two stages, this study refines the classic definition of commutation failure. Then, taking singlephase harmonic voltage disturbances at the receiving-end converter bus as an example, the commutation voltage time area method is employed to comprehensively analyze harmonics of different orders, amplitudes, and phases. This approach identifies critical intervals of harmonics that may trigger the first commutation failure. For scenarios involving multiple harmonic disturbances in a single phase, a numerical evaluation method is proposed to determine whether commutation failure occurs. Finally, the effectiveness of the proposed risk assessment method is validated using the electromagnetic transient simulation platform (PSCAD/EMTDC).

Authors

Institutions

Publication Details

Published
2025-04-25
DOI
https://doi.org/10.1109/aaiee64965.2025.11101252
Citations
1
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Risk Assessment of First Commutation Failure Caused by Single-phase Harmonic Voltage

Fei Liu
1 citations
Electrical Fault Detection and Protection
0.73
article

Risk Assessment of First Commutation Failure Caused by Single-phase Harmonic Voltage

Fei Liu
article en
1 citations

Abstract

Commutation failure is a research hotspot in the field of line commutated converter-based high voltage direct current transmission (LCC-HVDC). Current studies primarily focus on commutation failures caused by AC system faults, while research on harmonic voltage-induced commutation failures requires further exploration. First, starting from the mechanism of commutation failure and combining the analysis of a commutation process involving two stages, this study refines the classic definition of commutation failure. Then, taking singlephase harmonic voltage disturbances at the receiving-end converter bus as an example, the commutation voltage time area method is employed to comprehensively analyze harmonics of different orders, amplitudes, and phases. This approach identifies critical intervals of harmonics that may trigger the first commutation failure. For scenarios involving multiple harmonic disturbances in a single phase, a numerical evaluation method is proposed to determine whether commutation failure occurs. Finally, the effectiveness of the proposed risk assessment method is validated using the electromagnetic transient simulation platform (PSCAD/EMTDC).

Shandong University (CN)
Affordable and clean energy
Openalex Percentile: Top 25%
Electrical Fault Detection and Protection
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.