Joint arthroplasty has shown favorable outcomes across various anatomical sites; however, complications such as peri-prosthetic joint infection (PJI) remain challenging. Despite the importance of understanding surgical field contamination, many details are unclear. This study aimed to evaluate the contamination status of the surgical field during joint arthroplasty procedures. A prospective study was conducted on 150 joint arthroplasty cases at a single institution, involving 38 men and 112 women with a mean age of 68.8 years. The cohort included 41 total shoulder arthroplasty (TSA), 31 total knee arthroplasty (TKA), and 78 total hip arthroplasty (THA) procedures. Bacterial cultures, including anaerobic cultures, were obtained from three sites: (1) the surgical scalpel immediately after skin incision; (2) the surface of the surgical tray where the instruments were placed at the end of the procedure; and (3) the hands and chest area of the surgeon's gown. No early PJIs or bacterial growth was observed post-surgery. However, bacterial contamination was detected in 7 cases (4.7%), primarily in surgical trays. Cutibacterium acnes was identified in two TSA cases and one case each of TKA and THA. Other bacterial species detected included Staphylococcus hominis and Corynebacterium species. Additionally, Micrococcus luteus was found on the surgical gown of one TKA case. Contaminated cases showed significantly higher body weight ( p ​= ​0.036) and longer surgery time ( p ​= ​0.044) compared with non-contaminated cases. Maintaining an aseptic surgical environment, particularly in trays and gowns, is essential in preventing bacterial contamination, particularly C. acnes , during joint arthroplasty procedures. • Evaluation of intra-operative contamination during joint arthroplasty. • Bacterial contamination was detected in 4.7% of cases, mainly on instrument trays. • Cutibacterium acnes was the most commonly identified organism. • Contaminated cases had significantly higher body weight and longer surgery time. • Maintaining aseptic conditions, especially for trays and gowns, is crucial.

Authors

Institutions

Publication Details

Journal
Journal of Joint Surgery and Research
Published
2025-08-08
DOI
https://doi.org/10.1016/j.jjoisr.2025.07.002
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Surgical field contamination analysis in various artificial joint arthroplasties

Tatsuaki Matsumoto, Akihito Oya, Masaya Nakamura, Kengo Harato et al.
1 links
Journal of Joint Surgery and Research
Orthopaedic implants and arthroplasty
article

Surgical field contamination analysis in various artificial joint arthroplasties

Tatsuaki Matsumoto, Akihito Oya, Masaya Nakamura, Kengo Harato, Mitsuru Yagi, Kazuya Kaneda, Atsuhiro Fujie, Robert Nakayama, Noboru Matsumura, Morio Matsumoto, Taku Suzuki, Shu Kobayashi
article en

Abstract

Joint arthroplasty has shown favorable outcomes across various anatomical sites; however, complications such as peri-prosthetic joint infection (PJI) remain challenging. Despite the importance of understanding surgical field contamination, many details are unclear. This study aimed to evaluate the contamination status of the surgical field during joint arthroplasty procedures. A prospective study was conducted on 150 joint arthroplasty cases at a single institution, involving 38 men and 112 women with a mean age of 68.8 years. The cohort included 41 total shoulder arthroplasty (TSA), 31 total knee arthroplasty (TKA), and 78 total hip arthroplasty (THA) procedures. Bacterial cultures, including anaerobic cultures, were obtained from three sites: (1) the surgical scalpel immediately after skin incision; (2) the surface of the surgical tray where the instruments were placed at the end of the procedure; and (3) the hands and chest area of the surgeon's gown. No early PJIs or bacterial growth was observed post-surgery. However, bacterial contamination was detected in 7 cases (4.7%), primarily in surgical trays. Cutibacterium acnes was identified in two TSA cases and one case each of TKA and THA. Other bacterial species detected included Staphylococcus hominis and Corynebacterium species. Additionally, Micrococcus luteus was found on the surgical gown of one TKA case. Contaminated cases showed significantly higher body weight ( p ​= ​0.036) and longer surgery time ( p ​= ​0.044) compared with non-contaminated cases. Maintaining an aseptic surgical environment, particularly in trays and gowns, is essential in preventing bacterial contamination, particularly C. acnes , during joint arthroplasty procedures. • Evaluation of intra-operative contamination during joint arthroplasty. • Bacterial contamination was detected in 4.7% of cases, mainly on instrument trays. • Cutibacterium acnes was the most commonly identified organism. • Contaminated cases had significantly higher body weight and longer surgery time. • Maintaining aseptic conditions, especially for trays and gowns, is crucial.

Journal of Joint Surgery and ResearchVol. 3(3)
Keio University (JP), Keio University Hospital (JP), International University of Health and Welfare (JP)
Zero hunger
Openalex Percentile: Top 66%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.