Design of Flexible Arc Suppression System for Ground Fault in Distribution Network Based on Proportional Integral Control

When a single-phase grounding fault occurs in the distribution network, it may lead to fire accidents if the fault arc cannot be suppressed in time. The active arc suppression device can effectively suppress the grounding fault current. Based on this, the basic principle of flexible arc suppression in the distribution network is analyzed, and the magnitude of the current that needs to be injected to achieve fault arc suppression when a single-phase grounding fault occurs in the distribution network has been derived. It is verified that the magnitude of the injected current is independent of the resistance value of the grounding fault. Aiming at controlling the fault phase voltage to $\mathbf{0}$, a dual-closed-loop PI control method based on a voltage outer loop and a current inner loop is proposed, which does not require measuring the grounding parameters of the distribution network, thus improving the system’s response speed. The amplitude-frequency curve and root locus method are used to analyze the suppression effect and stability of the system. Under the premise of ensuring system stability, the parameters of the dual-loop controller with optimal arc suppression effect are obtained.

Authors

Publication Details

Published
2025-04-25
DOI
https://doi.org/10.1109/aaiee64965.2025.11100396
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of Flexible Arc Suppression System for Ground Fault in Distribution Network Based on Proportional Integral Control

Liang Yufeng, Yue Yang, Yifan Ding, Xiaowei Wang et al.
Power Systems and Technologies
article

Design of Flexible Arc Suppression System for Ground Fault in Distribution Network Based on Proportional Integral Control

Liang Yufeng, Yue Yang, Yifan Ding, Xiaowei Wang, Zhu Shen, Zhihua Huang, Ying Liu
article en

Abstract

When a single-phase grounding fault occurs in the distribution network, it may lead to fire accidents if the fault arc cannot be suppressed in time. The active arc suppression device can effectively suppress the grounding fault current. Based on this, the basic principle of flexible arc suppression in the distribution network is analyzed, and the magnitude of the current that needs to be injected to achieve fault arc suppression when a single-phase grounding fault occurs in the distribution network has been derived. It is verified that the magnitude of the injected current is independent of the resistance value of the grounding fault. Aiming at controlling the fault phase voltage to $\mathbf{0}$, a dual-closed-loop PI control method based on a voltage outer loop and a current inner loop is proposed, which does not require measuring the grounding parameters of the distribution network, thus improving the system’s response speed. The amplitude-frequency curve and root locus method are used to analyze the suppression effect and stability of the system. Under the premise of ensuring system stability, the parameters of the dual-loop controller with optimal arc suppression effect are obtained.

Climate action
Openalex Percentile: Top 81%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design of Flexible Arc Suppression System for Ground Fault in Distribution Network Based on Proportional Integral Control — Liang Yufeng, Yue Yang, et al. · (2025) | TGRS Research Map | TGRS