Shock wave attenuation characteristics in the Tesla valve

A Tesla valve is a passive unidirectional flow conduit designed with specialized geometric. For reverse flow, the interaction between the channel and fluid results in energy dissipation and pressure reduction. As a kind of fluid characterized by high Reynolds numbers, a shock wave can also be attenuated by Tesla valves. If this attenuation can be controlled, it will offer a new approach to solving the challenge of measuring high-pressure shock wave parameters in near-field explosions. We use numerical methods to investigate the attenuation characteristics of shock waves within the Tesla valve, clarifying the influence of different Tesla valve geometric and load parameters on the attenuation effect. The results show that a Tesla valve with two basic units produces two pressure peaks at its inlet and four peaks at the outlet. We also found that reducing the inner diameter d and increasing the incident load intensity both improve the attenuation rate and the diodicity. However, increasing the diversion angle α results in a higher pressure attenuation rate but lower diodicity. In addition, increasing α also prolongs the time interval between the overpressure and the flow velocity reaching the maximum value, respectively, thus realizing the effect of decoupling the overpressure and the dynamic pressure in time. This paper identifies the relationship between the geometric parameters of the Tesla valve and the shock wave pressure attenuation rate and diodicity. These findings provide valuable references for the optimized design and performance prediction of Tesla valves in controlling the attenuation of shock waves.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2025-08-01
DOI
https://doi.org/10.1063/5.0281650
Primary Topic
Combustion and Detonation Processes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shock wave attenuation characteristics in the Tesla valve

Dongbao Wang, Yuwu Zhang, Zizhen Qi, Wen Yan Liang et al.
Physics of Fluids
Combustion and Detonation Processes
article

Shock wave attenuation characteristics in the Tesla valve

Dongbao Wang, Yuwu Zhang, Zizhen Qi, Wen Yan Liang, Jinglan Zhou, Minzu Liang, Yuliang Lin
article en

Abstract

A Tesla valve is a passive unidirectional flow conduit designed with specialized geometric. For reverse flow, the interaction between the channel and fluid results in energy dissipation and pressure reduction. As a kind of fluid characterized by high Reynolds numbers, a shock wave can also be attenuated by Tesla valves. If this attenuation can be controlled, it will offer a new approach to solving the challenge of measuring high-pressure shock wave parameters in near-field explosions. We use numerical methods to investigate the attenuation characteristics of shock waves within the Tesla valve, clarifying the influence of different Tesla valve geometric and load parameters on the attenuation effect. The results show that a Tesla valve with two basic units produces two pressure peaks at its inlet and four peaks at the outlet. We also found that reducing the inner diameter d and increasing the incident load intensity both improve the attenuation rate and the diodicity. However, increasing the diversion angle α results in a higher pressure attenuation rate but lower diodicity. In addition, increasing α also prolongs the time interval between the overpressure and the flow velocity reaching the maximum value, respectively, thus realizing the effect of decoupling the overpressure and the dynamic pressure in time. This paper identifies the relationship between the geometric parameters of the Tesla valve and the shock wave pressure attenuation rate and diodicity. These findings provide valuable references for the optimized design and performance prediction of Tesla valves in controlling the attenuation of shock waves.

Physics of FluidsVol. 37(8)
National University of Defense Technology (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 71%
Combustion and Detonation Processes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.