Does a Dual-Mobility Cup Offer Better Stability than Conventional Bearings in Hip Arthroplasty Following Femoral Neck Fracture?

<b>Introduction:</b> Instability following total hip arthroplasty (THA) remains a challenging complication. Dual-mobility (DM) hip components are aimed at improving joint stability by increasing the head-neck ratio and jump distance. However, data regarding the efficacy of these implants in the trauma setting are scarce. This study aimed to compare the dislocation rates of DM bearings with conventional THA in patients undergoing primary THA for the treatment of hip fractures. <b>Methods:</b> We retrospectively reviewed all patients who underwent THA for hip fractures between the years 2010-2022 and had a minimum follow-up of two years. Patient demographics and radiographic parameters, including cup version, leg length discrepancy (LLD) and femoral horizontal offset, were compared between patients who received DM bearings and patients who received conventional THA. Dislocation and revision surgery rates were also compared between the groups. <b>Results:</b> The study included 570 patients who met inclusion criteria, of which 82 patients were in the DM bearings group and 488 patients were in the conventional THA group. Baseline demographics and comorbidity profiles were comparable between the groups. Cup anteversion was significantly lower in the DM group (11.1° vs. 14.1°; <i>p</i> = 0.006), while no significant differences were observed in LLD nor femoral offset between the groups (<i>p</i> = 0.38, <i>p</i> = 0.69, respectively). Dislocation rates were similar between the DM and conventional THA groups (1.2% vs. 1.02%, respectively; <i>p</i> = 0.54). Furthermore, revision rates were similar between DM and conventional THA (1.22% vs. 2.87%, respectively; <i>p</i> = 0.387). <b>Conclusions:</b> While no significant differences in dislocation rates were observed between dual-mobility and conventional THA bearings, the significantly lower cup anteversion suggests a potential improvement in acetabular safe zone positioning, this could reflect a broader margin for error in implant positioning. Further prospective studies are needed to elucidate the biomechanical advantages of DM bearings in patients with hip fractures.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-08-08
DOI
https://doi.org/10.3390/jcm14165613
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Does a Dual-Mobility Cup Offer Better Stability than Conventional Bearings in Hip Arthroplasty Following Femoral Neck Fracture?

Aviram Gold, Nimrod Snir, Itay Ashkenazi, Yaniv Warschawski et al.
Journal of Clinical Medicine
Hip and Femur Fractures
article

Does a Dual-Mobility Cup Offer Better Stability than Conventional Bearings in Hip Arthroplasty Following Femoral Neck Fracture?

Aviram Gold, Nimrod Snir, Itay Ashkenazi, Yaniv Warschawski, Itay Ron
article en

Abstract

<b>Introduction:</b> Instability following total hip arthroplasty (THA) remains a challenging complication. Dual-mobility (DM) hip components are aimed at improving joint stability by increasing the head-neck ratio and jump distance. However, data regarding the efficacy of these implants in the trauma setting are scarce. This study aimed to compare the dislocation rates of DM bearings with conventional THA in patients undergoing primary THA for the treatment of hip fractures. <b>Methods:</b> We retrospectively reviewed all patients who underwent THA for hip fractures between the years 2010-2022 and had a minimum follow-up of two years. Patient demographics and radiographic parameters, including cup version, leg length discrepancy (LLD) and femoral horizontal offset, were compared between patients who received DM bearings and patients who received conventional THA. Dislocation and revision surgery rates were also compared between the groups. <b>Results:</b> The study included 570 patients who met inclusion criteria, of which 82 patients were in the DM bearings group and 488 patients were in the conventional THA group. Baseline demographics and comorbidity profiles were comparable between the groups. Cup anteversion was significantly lower in the DM group (11.1° vs. 14.1°; <i>p</i> = 0.006), while no significant differences were observed in LLD nor femoral offset between the groups (<i>p</i> = 0.38, <i>p</i> = 0.69, respectively). Dislocation rates were similar between the DM and conventional THA groups (1.2% vs. 1.02%, respectively; <i>p</i> = 0.54). Furthermore, revision rates were similar between DM and conventional THA (1.22% vs. 2.87%, respectively; <i>p</i> = 0.387). <b>Conclusions:</b> While no significant differences in dislocation rates were observed between dual-mobility and conventional THA bearings, the significantly lower cup anteversion suggests a potential improvement in acetabular safe zone positioning, this could reflect a broader margin for error in implant positioning. Further prospective studies are needed to elucidate the biomechanical advantages of DM bearings in patients with hip fractures.

Journal of Clinical MedicineVol. 14(16)
Technion – Israel Institute of Technology (IL), Tel Aviv Sourasky Medical Center (IL)
Openalex Percentile: Top 66%
Hip and Femur Fractures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.