Two-Stage Power Delivery Architecture Using Hybrid Converters for Data Centers and Telecommunication Systems

This paper presents a new power delivery architecture to bring AC distribution voltages to core levels for computing loads using only two conversion stages with new converter topologies to potentially replace the traditional four-stage structure in the development of new data centers. This paper also includes new converters as solutions to the proposed two stages. A new switched capacitor (SC)-based AC-DC converter is proposed for the first stage and demonstrated for an intermediate bus with 90 V–110 VAC to 48–60 VDC conversion and power factor correction. The second stage also includes an SC-based hybrid converter with multi-phase operation suitable for power delivery for core voltages of up to ~1 V with a high current density. This work also reports a new phase sequence for the second stage for an extended output voltage range. Individually, the first stage was measured at 96.1% peak efficiency for output currents ranging from 0 to 4.5 A, while the second stage achieved 90.7% peak efficiency with a load range of 0–220 A at 1V. The measured peak power densities were 73 W/in3 for the first stage and 2020 W/in3 for the second stage. In combination, the direct conversion from ~110 VAC to 1 VDC led to a peak efficiency of 84.1% at 50 A, and this setup has been tested with output currents of up to 160 A, where the efficiency was 73.5%.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-08-08
DOI
https://doi.org/10.3390/electronics14163169
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-Stage Power Delivery Architecture Using Hybrid Converters for Data Centers and Telecommunication Systems

Hanh‐Phuc Le, Ratul Das
Electronics
Advanced DC-DC Converters
article

Two-Stage Power Delivery Architecture Using Hybrid Converters for Data Centers and Telecommunication Systems

Hanh‐Phuc Le, Ratul Das
article en

Abstract

This paper presents a new power delivery architecture to bring AC distribution voltages to core levels for computing loads using only two conversion stages with new converter topologies to potentially replace the traditional four-stage structure in the development of new data centers. This paper also includes new converters as solutions to the proposed two stages. A new switched capacitor (SC)-based AC-DC converter is proposed for the first stage and demonstrated for an intermediate bus with 90 V–110 VAC to 48–60 VDC conversion and power factor correction. The second stage also includes an SC-based hybrid converter with multi-phase operation suitable for power delivery for core voltages of up to ~1 V with a high current density. This work also reports a new phase sequence for the second stage for an extended output voltage range. Individually, the first stage was measured at 96.1% peak efficiency for output currents ranging from 0 to 4.5 A, while the second stage achieved 90.7% peak efficiency with a load range of 0–220 A at 1V. The measured peak power densities were 73 W/in3 for the first stage and 2020 W/in3 for the second stage. In combination, the direct conversion from ~110 VAC to 1 VDC led to a peak efficiency of 84.1% at 50 A, and this setup has been tested with output currents of up to 160 A, where the efficiency was 73.5%.

ElectronicsVol. 14(16)
University of Minnesota (US), University of California San Diego (US), Jacobs (United States) (US)
National Science Foundation, Division of Electrical, Communications and Cyber Systems
Affordable and clean energy
Openalex Percentile: Top 81%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Two-Stage Power Delivery Architecture Using Hybrid Converters for Data Centers and Telecommunication Systems — Hanh‐Phuc Le, Ratul Das · Electronics (2025) | TGRS Research Map | TGRS