An experimental study on two-phase flashing R134a spray cooling performance with multiple nozzles

Low-boiling-point R134a spray cooling effectively reduces surface temperatures rapidly, with applications in chip cooling, automotive air conditioning, and laser biomedicine. Multiple nozzles have a larger spray coverage and liquid film spreading area compared to a single nozzle, allowing for enhanced convective and phase-change heat transfer, leading to large-area uniform cooling and flexible adjustment of cooling capacity. An experimental apparatus for cryogen spray cooling was set up to analyze the effects of various factors, including nozzle inner diameter, spray distance, spray pressure, spurt duration, and cooling substrate, on the surface heat transfer characteristics. The results indicate that the lowest surface temperature is primarily influenced by the nozzle inner diameter and spray distance, while the peak heat flux is mainly affected by the spray distance and the cooling substrate. The heat flux with copper surface is ∼38 times that of an epoxy resin block (qmax = 8179.94 kW/m2). Nozzle diameter has the most significant impact on the uniformity of surface cooling, whereas spray pressure and duration have the weakest effects on surface heat transfer characteristics. When the cooling substrate is an epoxy resin block, appropriate spray conditions (Nozzle diameter D = 0.4 mm, spray pressure P = 1.9 MPa, spray distance H = 10 mm, and spurt duration ts= 50 ms) allow droplets to fully atomize and distribute reasonably across the surface, achieving the lowest cooling temperature (Tmin = −40.13 °C) and the highest heat flux (qmax = 217.76 kW/m2) as well as realizing a longer effective cooling time.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2025-08-01
DOI
https://doi.org/10.1063/5.0279211
Citations
2
Primary Topic
Fluid Dynamics and Heat Transfer
Type
article
Field-Weighted Citation Impact
2.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An experimental study on two-phase flashing R134a spray cooling performance with multiple nozzles

Jiameng Tian, Hongli Zhao, Bin Chen, Zhifu Zhou et al.
2 citations
Physics of Fluids
Fluid Dynamics and Heat Transfer
2.67
article

An experimental study on two-phase flashing R134a spray cooling performance with multiple nozzles

Jiameng Tian, Hongli Zhao, Bin Chen, Zhifu Zhou, Dong Li, Tao Ma, Zhi Li, Xiaoyang Li, Yifeng Liu, Tianning Zhang, Lizheng Su
article en
2 citations

Abstract

Low-boiling-point R134a spray cooling effectively reduces surface temperatures rapidly, with applications in chip cooling, automotive air conditioning, and laser biomedicine. Multiple nozzles have a larger spray coverage and liquid film spreading area compared to a single nozzle, allowing for enhanced convective and phase-change heat transfer, leading to large-area uniform cooling and flexible adjustment of cooling capacity. An experimental apparatus for cryogen spray cooling was set up to analyze the effects of various factors, including nozzle inner diameter, spray distance, spray pressure, spurt duration, and cooling substrate, on the surface heat transfer characteristics. The results indicate that the lowest surface temperature is primarily influenced by the nozzle inner diameter and spray distance, while the peak heat flux is mainly affected by the spray distance and the cooling substrate. The heat flux with copper surface is ∼38 times that of an epoxy resin block (qmax = 8179.94 kW/m2). Nozzle diameter has the most significant impact on the uniformity of surface cooling, whereas spray pressure and duration have the weakest effects on surface heat transfer characteristics. When the cooling substrate is an epoxy resin block, appropriate spray conditions (Nozzle diameter D = 0.4 mm, spray pressure P = 1.9 MPa, spray distance H = 10 mm, and spurt duration ts= 50 ms) allow droplets to fully atomize and distribute reasonably across the surface, achieving the lowest cooling temperature (Tmin = −40.13 °C) and the highest heat flux (qmax = 217.76 kW/m2) as well as realizing a longer effective cooling time.

Physics of FluidsVol. 37(8)
Jiangsu University (CN), Microbiology Institute of Shaanxi (CN), Xi'an Jiaotong University (CN)
National Natural Science Foundation of China, Key Research and Development Projects of Shaanxi Province
Affordable and clean energy
Openalex Percentile: Top 10%
Fluid Dynamics and Heat Transfer
2.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.