Design and Assembly of a Multi-Level Inverter for Motor Drive Applications

Abstract This study explored into the design and assembly of a multi-level inverter for motor drive applications, with a specific focus on the control system for an IM (IM) utilised in pumping applications. The control strategy combines Sinusoidal Pulse Width Modulation (SPWM) for modulation and Indirect Field Oriented Control (IFOC) for precise control. The IM (IM) receives power from a cascaded H-bridge multilevel inverter (CHBMLI), which is controlled using the Alternate Phase Opposition Disposition (APOD) multi-carrier PWM technique. To assess the system’s performance, a detailed mathematical model of the pump load is developed, and extensive simulations are performed. Additionally, the study verifies the affinity law of the centrifugal pump (CP) by comparing simulation results with theoretical predictions.. The rationale behind selecting a three-stage IM for industrial applications is attributed to its enduring robustness, reliability, and simplicity in construction. This research underscores the persistent quest for precision in controlling these motors, encompassing modulation techniques and advanced closed-loop control strategies.

Authors

Institutions

Publication Details

Journal
IOP Conference Series Earth and Environmental Science
Published
2025-08-01
DOI
https://doi.org/10.1088/1755-1315/1529/1/012020
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Assembly of a Multi-Level Inverter for Motor Drive Applications

Gandi Ramarao, Kalyana Kiran Kumar, Prasad Chongala, K.R.S. Prasad et al.
IOP Conference Series Earth and Environmental Science
Multilevel Inverters and Converters
article

Design and Assembly of a Multi-Level Inverter for Motor Drive Applications

Gandi Ramarao, Kalyana Kiran Kumar, Prasad Chongala, K.R.S. Prasad, Nakka Hemanth
article en

Abstract

Abstract This study explored into the design and assembly of a multi-level inverter for motor drive applications, with a specific focus on the control system for an IM (IM) utilised in pumping applications. The control strategy combines Sinusoidal Pulse Width Modulation (SPWM) for modulation and Indirect Field Oriented Control (IFOC) for precise control. The IM (IM) receives power from a cascaded H-bridge multilevel inverter (CHBMLI), which is controlled using the Alternate Phase Opposition Disposition (APOD) multi-carrier PWM technique. To assess the system’s performance, a detailed mathematical model of the pump load is developed, and extensive simulations are performed. Additionally, the study verifies the affinity law of the centrifugal pump (CP) by comparing simulation results with theoretical predictions.. The rationale behind selecting a three-stage IM for industrial applications is attributed to its enduring robustness, reliability, and simplicity in construction. This research underscores the persistent quest for precision in controlling these motors, encompassing modulation techniques and advanced closed-loop control strategies.

IOP Conference Series Earth and Environmental ScienceVol. 1529(1)
Aditya Birla (India) (IN), Indian Institute of Management Visakhapatnam (IN)
Openalex Percentile: Top 47%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.