Frequency Control Method Utilising the Potential of Recovery Process of the ON/OFF Flexible Loads

ABSTRACT ON/OFF flexible loads (FLs), which account for a large proportion of demand side resources, have been proved to be effective in the frequency control of the power systems. The recovery process, which is essential for ON/OFF FLs, requires FLs to recover to their original ON/OFF status after activated. Other than thermostatically controlled loads (TCLs), non‐TCLs cannot realise recovery through natural switching. The recovery control of non‐TCLs may limit the capacity of bi‐directional frequency control. Focusing on this problem, this paper proposes a bi‐directional frequency control method which fully utilises the ON/OFF FLs in the recovery‐process. By defining a combined fast‐and‐slow recovery‐process (CFSRP), the activated ON/OFF FLs can still provide active power regulation service during their fast recovery‐process (FRP). By designing a hierarchical strategy that considers bi‐directional frequency control, the available regulation capacity of FLs and the frequency control capacity are increased. The case study results show that, compared to traditional methods that do not consider the CFSRP strategy, the proposed method reduces the maximum frequency deviation by over 4%.

Authors

Institutions

Publication Details

Journal
IET Energy Systems Integration
Published
2025-01-01
DOI
https://doi.org/10.1049/esi2.70014
Primary Topic
Smart Grid Energy Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frequency Control Method Utilising the Potential of Recovery Process of the ON/OFF Flexible Loads

Zi‐Li Yao, Ying Chen, Yu‐Qing Bao
IET Energy Systems Integration
Smart Grid Energy Management
article

Frequency Control Method Utilising the Potential of Recovery Process of the ON/OFF Flexible Loads

Zi‐Li Yao, Ying Chen, Yu‐Qing Bao
article en

Abstract

ABSTRACT ON/OFF flexible loads (FLs), which account for a large proportion of demand side resources, have been proved to be effective in the frequency control of the power systems. The recovery process, which is essential for ON/OFF FLs, requires FLs to recover to their original ON/OFF status after activated. Other than thermostatically controlled loads (TCLs), non‐TCLs cannot realise recovery through natural switching. The recovery control of non‐TCLs may limit the capacity of bi‐directional frequency control. Focusing on this problem, this paper proposes a bi‐directional frequency control method which fully utilises the ON/OFF FLs in the recovery‐process. By defining a combined fast‐and‐slow recovery‐process (CFSRP), the activated ON/OFF FLs can still provide active power regulation service during their fast recovery‐process (FRP). By designing a hierarchical strategy that considers bi‐directional frequency control, the available regulation capacity of FLs and the frequency control capacity are increased. The case study results show that, compared to traditional methods that do not consider the CFSRP strategy, the proposed method reduces the maximum frequency deviation by over 4%.

IET Energy Systems IntegrationVol. 7(1)
Nanjing Normal University (CN), Shanghai Electric (China) (CN), The First People’s Hospital of Lianyungang (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 81%
Smart Grid Energy Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.