Highly Sensitive Dopamine Electrochemical Sensor Using Pt Nanoparticles on CNTs/Polypyrrole Nanocomposites

ABSTRACT Dopamine (DA) plays a vital role as a neurotransmitter in the central nervous system (CNS), and its accurate quantification is essential for diagnosing neurological disorders. However, selective and sensitive detection of DA in complex biological matrices remains a challenge due to interference from coexisting biomolecules. In this study, a platinum nanoparticle‐decorated carbon nanotubes/polypyrrole‐carbon (Pt@CNTs/PPy‐C) nanocomposite was synthesized via a facile two‐step process involving ultrasonication and photo‐reduction, eliminating the need for stabilizers or dispersants. Structural and morphological analysis confirmed the uniform distribution of Pt nanoparticles within the CNTs/PPy‐C matrix, enhancing electrocatalytic activity. Electrochemical kinetic studies revealed that DA electro‐oxidation on the nanocomposite‐modified glassy carbon electrode (GCE) follows adsorption‐controlled kinetics, with a transfer coefficient ( α ) of 0.51 and a heterogeneous rate constant of 8.37 s −1 . Differential pulse voltammetry (DPV) demonstrated a high sensitivity of 3.45 µA µM −1 cm −2 over a linear range of 2.0–24.0 µM with a detection limit of 0.034 µM. The sensor exhibited outstanding selectivity for DA in the presence of various interfering species, along with excellent reproducibility, repeatability and stability. Additionally, the sensor demonstrated high accuracy and reliability in detecting DA in a commercial pharmaceutical formulation, with recovery rates ranging from 96.72% to 101.40%. These findings highlight the potential of the Pt@CNTs/PPy‐C nanocomposite as a promising electrocatalyst for DA detection, contributing to the development of highly efficient electrochemical sensors for biomedical and pharmaceutical applications.

Authors

Institutions

Publication Details

Journal
Electrochemical Science Advances
Published
2025-08-10
DOI
https://doi.org/10.1002/elsa.70011
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly Sensitive Dopamine Electrochemical Sensor Using Pt Nanoparticles on CNTs/Polypyrrole Nanocomposites

Jahir Ahmed, Jari S. Algethami, Ahmed Mohamed El‐Toni, Farid A. Harraz et al.
1 citations
Electrochemical Science Advances
Electrochemical sensors and biosensors
0.73
article

Highly Sensitive Dopamine Electrochemical Sensor Using Pt Nanoparticles on CNTs/Polypyrrole Nanocomposites

Jahir Ahmed, Jari S. Algethami, Ahmed Mohamed El‐Toni, Farid A. Harraz, Md. A. Rashed, Mohd Faisal, N. I. Nayem, Sohail Ahmed
article en
1 citations

Abstract

ABSTRACT Dopamine (DA) plays a vital role as a neurotransmitter in the central nervous system (CNS), and its accurate quantification is essential for diagnosing neurological disorders. However, selective and sensitive detection of DA in complex biological matrices remains a challenge due to interference from coexisting biomolecules. In this study, a platinum nanoparticle‐decorated carbon nanotubes/polypyrrole‐carbon (Pt@CNTs/PPy‐C) nanocomposite was synthesized via a facile two‐step process involving ultrasonication and photo‐reduction, eliminating the need for stabilizers or dispersants. Structural and morphological analysis confirmed the uniform distribution of Pt nanoparticles within the CNTs/PPy‐C matrix, enhancing electrocatalytic activity. Electrochemical kinetic studies revealed that DA electro‐oxidation on the nanocomposite‐modified glassy carbon electrode (GCE) follows adsorption‐controlled kinetics, with a transfer coefficient ( α ) of 0.51 and a heterogeneous rate constant of 8.37 s −1 . Differential pulse voltammetry (DPV) demonstrated a high sensitivity of 3.45 µA µM −1 cm −2 over a linear range of 2.0–24.0 µM with a detection limit of 0.034 µM. The sensor exhibited outstanding selectivity for DA in the presence of various interfering species, along with excellent reproducibility, repeatability and stability. Additionally, the sensor demonstrated high accuracy and reliability in detecting DA in a commercial pharmaceutical formulation, with recovery rates ranging from 96.72% to 101.40%. These findings highlight the potential of the Pt@CNTs/PPy‐C nanocomposite as a promising electrocatalyst for DA detection, contributing to the development of highly efficient electrochemical sensors for biomedical and pharmaceutical applications.

Electrochemical Science AdvancesVol. 6(1)
King Saud University (SA), Mawlana Bhashani Science and Technology University (BD), Najran University (SA)
Najran University
Openalex Percentile: Top 25%
Electrochemical sensors and biosensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.