Muscle forces and powers during sprint cycling at optimal cadence

This study describes lower limb musculotendon unit (MTU) forces and powers during sprint cycling. Seven participants (2 female) performed maximal effort cycling at optimal cadence. Three-dimensional motion capture, pedal forces, and surface electromyography (EMG) data were input into participant-calibrated EMG-informed neuromusculoskeletal models to evaluate forces and powers produced by 18 lower-limb MTUs. In the pushing phase (10° - 170°, relative to the right crank at top dead centre), the hip adductor group generated the highest average force (1623.78 ± 980.62 N) and the vastus lateralis generated the highest average positive power (193.11 ± 153.07 W). In the pulling phase (170°-350°), the hip adductor group generated the highest average force (1140.48 ± 482.57 N) and average power (60.47 ± 68.87 W). In the transition phase (350°-10°), the vastus lateralis generated the highest average force (1432.26 ± 1169.40 N) and average power (76.98 ± 71.84 W). MTU power crank cycle-profiles were generated for each participant, highlighting differences in patterns of MTU power generation. Future work is needed to determine if targeted training based on cyclist-specific MTU force and power model outputs would lead to improved sprint cycling performance.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanics
Published
2025-08-10
DOI
https://doi.org/10.1016/j.jbiomech.2025.112890
Citations
1
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Muscle forces and powers during sprint cycling at optimal cadence

Tyler Collings, Claire Crossley, Matthew Worsey, Thomas Wackwitz et al.
1 citations
Journal of Biomechanics
Muscle activation and electromyography studies
0.67
article

Muscle forces and powers during sprint cycling at optimal cadence

Tyler Collings, Claire Crossley, Matthew Worsey, Thomas Wackwitz, Claudio Pizzolato, Matthew N. Bourne
article en
1 citations

Abstract

This study describes lower limb musculotendon unit (MTU) forces and powers during sprint cycling. Seven participants (2 female) performed maximal effort cycling at optimal cadence. Three-dimensional motion capture, pedal forces, and surface electromyography (EMG) data were input into participant-calibrated EMG-informed neuromusculoskeletal models to evaluate forces and powers produced by 18 lower-limb MTUs. In the pushing phase (10° - 170°, relative to the right crank at top dead centre), the hip adductor group generated the highest average force (1623.78 ± 980.62 N) and the vastus lateralis generated the highest average positive power (193.11 ± 153.07 W). In the pulling phase (170°-350°), the hip adductor group generated the highest average force (1140.48 ± 482.57 N) and average power (60.47 ± 68.87 W). In the transition phase (350°-10°), the vastus lateralis generated the highest average force (1432.26 ± 1169.40 N) and average power (76.98 ± 71.84 W). MTU power crank cycle-profiles were generated for each participant, highlighting differences in patterns of MTU power generation. Future work is needed to determine if targeted training based on cyclist-specific MTU force and power model outputs would lead to improved sprint cycling performance.

Journal of BiomechanicsVol. 191
Griffith University (AU)
Openalex Percentile: Top 28%
Muscle activation and electromyography studies
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.