Distribution Feeder Fault Detection Method Considering Transient Frequency Response of Distributed Power Supply

ABSTRACT Single‐phase ground faults can occur in distribution networks, which bring harm to the safe operation of distribution networks. With the continuous development of new energy technology, distributed power supply is also accessed to the distribution network in large quantities. This paper analysed the impact of distributed power supply from the perspective of its transient frequency response. It explores the changing rules and characteristics of the fault travelling wave in the frequency and time domains, revealing its time–frequency–amplitude three‐dimensional characteristics. Accordingly, a detection method based on energy distribution characteristics is proposed, and the thresholds for startup and fault detection are given. The sensitivity of the startup criterion and the accuracy of fault detection are verified through simulation analysis, and the method is able to identify transient disturbances and faults, and also has a certain anti‐interference ability. In addition, experimental validation was carried out in a physical test field, and the results show that the proposed method is applicable in practical application scenarios.

Authors

Institutions

Publication Details

Journal
IET Smart Grid
Published
2025-01-01
DOI
https://doi.org/10.1049/stg2.70031
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Distribution Feeder Fault Detection Method Considering Transient Frequency Response of Distributed Power Supply

Zhongqiang Zhou, Zhi Zhou, Jupeng Zeng, Xiang Liao et al.
IET Smart Grid
Power Systems Fault Detection
article

Distribution Feeder Fault Detection Method Considering Transient Frequency Response of Distributed Power Supply

Zhongqiang Zhou, Zhi Zhou, Jupeng Zeng, Xiang Liao, Yunlong Xia, Wen Yuan, Moujun Deng
article en

Abstract

ABSTRACT Single‐phase ground faults can occur in distribution networks, which bring harm to the safe operation of distribution networks. With the continuous development of new energy technology, distributed power supply is also accessed to the distribution network in large quantities. This paper analysed the impact of distributed power supply from the perspective of its transient frequency response. It explores the changing rules and characteristics of the fault travelling wave in the frequency and time domains, revealing its time–frequency–amplitude three‐dimensional characteristics. Accordingly, a detection method based on energy distribution characteristics is proposed, and the thresholds for startup and fault detection are given. The sensitivity of the startup criterion and the accuracy of fault detection are verified through simulation analysis, and the method is able to identify transient disturbances and faults, and also has a certain anti‐interference ability. In addition, experimental validation was carried out in a physical test field, and the results show that the proposed method is applicable in practical application scenarios.

IET Smart GridVol. 8(1)
Guizhou Electric Power Design and Research Institute (CN), Changsha University of Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 75%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.