Experimental investigations and design of precast concrete‐filled steel corrugated sheet slender columns with intermediate connection

Abstract Concrete‐filled steel corrugated sheet (CFSCS) offers confinement to the core concrete while the outer galvanized corrugated steel sheet (GCSS) offers excellent corrosion resistance. Application of precast multiple CFSCS columns connected through high‐performance concrete (HPC) in constructing a slender column offers ease of construction while offering excellent quality control due to casting off‐site in a controlled environment. However, there has been no research carried out to examine the performance of precast CFSCS columns with an outer CSS profile and intermediate connections filled with HPC. To fill this knowledge gap, this paper examines the performance of precast CFSCS slender columns subjected to axial compression load. The effects of various types of HPC as an intermediate connection, namely polypropylene fiber reinforced concrete (PPFRC), ultra‐high‐performance engineered cementitious composite (UHPECC), and ultra‐high‐performance steel fiber reinforced concrete (UHPSFRC) on the axial performance of CFSCS columns are examined. Furthermore, the effects of the embedded length of the reinforcement bars are examined by varying the embedded length from 10 D , 15 D , and 20 D , where D represents the diameter of the bar. It is found that applications of HPC concrete, namely PPFRC, UHPECC, and UHPSFRC as an intermediate connection, increase the column's structural performance significantly in contrast to the control specimen. The accuracy of the design specifications for circular SCC columns specified by existing design codes is examined to predict the ultimate load of the precast CFSCS slender columns. A reduction factor () to consider the column height in the ultimate load of the precast CFSCS columns is proposed based on the test results.

Authors

Institutions

Publication Details

Journal
Structural Concrete
Published
2025-08-10
DOI
https://doi.org/10.1002/suco.70301
Citations
1
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.95

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigations and design of precast concrete‐filled steel corrugated sheet slender columns with intermediate connection

Hussam Alghamdi, Aref A. Abadel, Mohammed M. Attia, Abedulgader Baktheer et al.
1 citations
Structural Concrete
Structural Load-Bearing Analysis
0.95
article

Experimental investigations and design of precast concrete‐filled steel corrugated sheet slender columns with intermediate connection

Hussam Alghamdi, Aref A. Abadel, Mohammed M. Attia, Abedulgader Baktheer, Ahmed Hamoda, Mohamed Emara, Mizan Ahmed
article en
1 citations

Abstract

Abstract Concrete‐filled steel corrugated sheet (CFSCS) offers confinement to the core concrete while the outer galvanized corrugated steel sheet (GCSS) offers excellent corrosion resistance. Application of precast multiple CFSCS columns connected through high‐performance concrete (HPC) in constructing a slender column offers ease of construction while offering excellent quality control due to casting off‐site in a controlled environment. However, there has been no research carried out to examine the performance of precast CFSCS columns with an outer CSS profile and intermediate connections filled with HPC. To fill this knowledge gap, this paper examines the performance of precast CFSCS slender columns subjected to axial compression load. The effects of various types of HPC as an intermediate connection, namely polypropylene fiber reinforced concrete (PPFRC), ultra‐high‐performance engineered cementitious composite (UHPECC), and ultra‐high‐performance steel fiber reinforced concrete (UHPSFRC) on the axial performance of CFSCS columns are examined. Furthermore, the effects of the embedded length of the reinforcement bars are examined by varying the embedded length from 10 D , 15 D , and 20 D , where D represents the diameter of the bar. It is found that applications of HPC concrete, namely PPFRC, UHPECC, and UHPSFRC as an intermediate connection, increase the column's structural performance significantly in contrast to the control specimen. The accuracy of the design specifications for circular SCC columns specified by existing design codes is examined to predict the ultimate load of the precast CFSCS slender columns. A reduction factor () to consider the column height in the ultimate load of the precast CFSCS columns is proposed based on the test results.

Structural ConcreteVol. 27(1)
Suez University (EG), Kafrelsheikh University (EG), Zagazig University (EG), Curtin University (AU), King Saud University (SA), RWTH Aachen University (DE)
King Saud University
Sustainable cities and communities
Openalex Percentile: Top 23%
Structural Load-Bearing Analysis
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.