Detection of Bacterial Contamination of Platelet Concentrates Produced at Selected Blood Processing Centres

Introduction: The most common microbiological cause of transfusion related morbidity and mortality is bacterial contamination of blood and its cellular components. Out of those cellular components, bacterial contamination of platelet concentrates is more common. Therefore, time-to-time detection of bacterial contamination of platelet concentrates produced at selected blood processing centers is crucial.Objective: To detect the pathogenic bacteria associated with bacterial contamination of platelet concentrates (PCs) produced at selected blood processing centers.Methodology: Single donor platelet units, prepared from different donations were used for this cross-sectional study. PCs which were injected into universal culture bottles, which contained Brain Heart Infusion (BHI) broth were observed for any evidence of growth. When there was any evidence of growth, those were inoculated on blood agar and chocolate agar, and a direct smear was prepared to perform a Gram stain. Particular biochemical tests were performed to identify the organism as far as possible. When there was no evidence of growth, only sub-culturing on blood agar and chocolate agar were done. All the bottles those showed negatives were re-incubated, and they were inspected daily. The above procedure was followed for up to 7 days.Results: Only three samples (3%) showed true positivity for contamination of both culture bottles. Therefore, the percentage of bacterial contamination of platelet concentrates at Day -7 was 3%. The isolated organism in all positive platelet concentrate units was a Gram-positive bacillus of the Bacillus species. Conclusion: Storing platelets at 22 °C up to 6 days and not extending the storage period are necessary to protect the sterility of platelets and to prevent platelet transfusion-associated adverse effects.

Authors

Publication Details

Journal
Sri Lanka Journal of Medicine
Published
2025-08-11
DOI
https://doi.org/10.4038/sljm.v34i2.577
Primary Topic
Blood transfusion and management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of Bacterial Contamination of Platelet Concentrates Produced at Selected Blood Processing Centres

W. K. H. Dheerasekara, E. P. P. A. Jayarathna, E. M. S. K. Senavirathna
Sri Lanka Journal of Medicine
Blood transfusion and management
article

Detection of Bacterial Contamination of Platelet Concentrates Produced at Selected Blood Processing Centres

W. K. H. Dheerasekara, E. P. P. A. Jayarathna, E. M. S. K. Senavirathna
article en

Abstract

Introduction: The most common microbiological cause of transfusion related morbidity and mortality is bacterial contamination of blood and its cellular components. Out of those cellular components, bacterial contamination of platelet concentrates is more common. Therefore, time-to-time detection of bacterial contamination of platelet concentrates produced at selected blood processing centers is crucial.Objective: To detect the pathogenic bacteria associated with bacterial contamination of platelet concentrates (PCs) produced at selected blood processing centers.Methodology: Single donor platelet units, prepared from different donations were used for this cross-sectional study. PCs which were injected into universal culture bottles, which contained Brain Heart Infusion (BHI) broth were observed for any evidence of growth. When there was any evidence of growth, those were inoculated on blood agar and chocolate agar, and a direct smear was prepared to perform a Gram stain. Particular biochemical tests were performed to identify the organism as far as possible. When there was no evidence of growth, only sub-culturing on blood agar and chocolate agar were done. All the bottles those showed negatives were re-incubated, and they were inspected daily. The above procedure was followed for up to 7 days.Results: Only three samples (3%) showed true positivity for contamination of both culture bottles. Therefore, the percentage of bacterial contamination of platelet concentrates at Day -7 was 3%. The isolated organism in all positive platelet concentrate units was a Gram-positive bacillus of the Bacillus species. Conclusion: Storing platelets at 22 °C up to 6 days and not extending the storage period are necessary to protect the sterility of platelets and to prevent platelet transfusion-associated adverse effects.

Sri Lanka Journal of MedicineVol. 34(2)
Good health and well-being
Openalex Percentile: Top 81%
Blood transfusion and management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detection of Bacterial Contamination of Platelet Concentrates Produced at Selected Blood Processing Centres — W. K. H. Dheerasekara, E. P. P. A. Jayarathna, et al. · Sri Lanka Journal of Medicine (2025) | TGRS Research Map | TGRS